Sequential injection with "Lab-at-Valve (LAV)" approach is demonstrated for potentiometric determination of chloride. The LAV flow-through electrode system consists of two Ag/AgCl electrodes: one as a reference electrode, silver chloride activated surface-silver wire soaked in a constant-concentration chloride ion solution in a small tube covered with a polymer-membrane, another as a working electrode (a similar silver chloride activated surface-silver wire) placed in a flow channel. The electrode system is attached at one port of a 10 port multiposition valve. A modified autoburette was used as a propelling device. Using SI operation via a program written in-house, based on LabVIEW((R)), a standard/sample is inserted, via the selection valve, in potassium nitrate as an electrolyte and water is used as a carrier. The zones are transported from the holding coil to the flow cell to monitor the difference in potential due to concentration cell behavior. The potential difference is then recorded as a peak. Peak height is proportional to logarithm of chloride concentration. The SI-LAV for chloride determination is very simple, fast, precise, accurate, automatic and economical. Applications to mineral drinking water and surface water have been made. The results agree with those of IC and titrimetric methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2004.08.007 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Department of Materials Science and Engineering, Feng Chia University, Taichung City, 40724, Taiwan.
The unique optical properties of perovskite quantum dots (PQDs), particularly the tunable photoluminescence (PL) across the visible spectrum, make them a promising tool for chlorinated detection. However, the correlation between the fluorescence emission shift behavior and the interface of phase transformation in PQDs has not been thoroughly explored. In this study, we synthesized CsPbBr PQDs via the hot-injection method and demonstrated their ability to detect chlorinated volatile compounds such as HCl and NaOCl through a halide exchange process between the PQDs' solid thin film and the chlorinated vapor phase.
View Article and Find Full Text PDFInt J Retina Vitreous
January 2025
Department of Ophthalmology and Visual Sciences, Federal University of São Paulo (UNIFESP), Rua Botucatu, 822, Vila Clementino, São Paulo/SP, 04023-062, Brazil.
Background: Ozurdex® (Allergan®, AbbVie Company, North Chicago, Illinois, EUA), is composed of 0.7 mg of dexamethasone, fused in a solid biodegradable PLGA polymer, whose degradation occurs naturally in the vitreous cavity, usually in six months after its application.
Methods: In this study, we included patients aged ≥ 18 years with one or two eyes who had an indication for Ozurdex implants.
Microb Pathog
January 2025
HEJ Research Institute of Chemistry, International Center for Chemical and Biological Sciences (ICCBS), University of Karachi, Karachi-75270, Pakistan; Dr. Panjwani Center for Molecular Medicine and Drug Research (PCMD), International Center for Chemical and Biological Sciences (ICCBS), University of Karachi, Karachi-75270, Pakistan. Electronic address:
Antimicrobial resistance (AMR) poses significant challenges to global public health. The major cause of AMR development is previous use of antibiotics, hospitalization, and the lack of efficient methods for screening AMR pathogens. Mass spectrometry techniques offer rapid, sensitive, and early detection of AMR both on proteomics and metabolomics levels.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
Institute of Novel Semiconductors, State Key Laboratory of Crystal Materials, Shandong University, 27 South Shanda Road, Shandong, 250100, P. R. China.
Acoustic frequency combs (AFCs) contain equidistant coherent signals with unconventional possibilities on metrology. Previously, implementation of AFCs on mechanical microresonators with large air damping loss is difficult, which restricted their atmospheric applications. In this work, we explore the potentials of a composite diamond/silicon microcantilever for parametric generation of AFCs in ambient air.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Sixth People's Hospital, School of Medicine & School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China.
The use of dual-tracer contrast agents in clinical applications, such as sentinel lymph node (SLN) identification, offers significant advantages including enhanced accuracy, sensitivity, as well as comprehensive and multimodal visualization. In the current clinical practice, SLNs are typically marked prior to surgical resection by multiple and sequential injections of two tracers, the radioactive tracer and methylene blue (MB) dye. This imposes physical and psychological burden on patients and medical staff.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!