A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A sequential injection method for the determination of piroxicam in pharmaceutical formulations using europium sensitized fluorescence. | LitMetric

A simple, selective and sensitive luminescence method for the assay of piroxicam (PX) in pharmaceutical formulation is developed. The method is based on the luminescence sensitization of europium (Eu(3+)) by complexation with PX. The signal for PX-EU is monitored at lambda(ex)=358nm and lambda(em)=615nm. Optimum conditions for the formation of the complex in methanol were 0.01M TRIS buffer and 0.2mM of Eu(3+) which allows the determination of 100-2000ppb of pX in batch method and 100-1000ppb with limit of detection (LOD) = 23.0ppb using sequential injection analysis (SIA). The relative standard deviations of the method range between 2 and 3% indicating excellent reproducibility of the method. The proposed method was successfully applied for he assay of PX in pharmaceutical formulations (Feldene capsules and tablets). Average recoveries of 101.0+/-0.3 and 98.8+/-2.7% were obtained for capsules in methanol using batch and sequential injection (SI) methods, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2004.04.014DOI Listing

Publication Analysis

Top Keywords

sequential injection
12
piroxicam pharmaceutical
8
pharmaceutical formulations
8
method
7
injection method
4
method determination
4
determination piroxicam
4
formulations europium
4
europium sensitized
4
sensitized fluorescence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!