Immunochemical determination of dioxins in sediment and serum samples.

Talanta

Department of Entomology, Cancer Research Center, University of California, 303 Briggs Hall, One Shields Avenue, Davis, CA 95616, USA.

Published: August 2004

Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants and the environmental and biological monitoring of these compounds is of great concern. Immunoassays may be used as screening methods to satisfy the growing demand for rapid and low cost analysis. In this work, we describe the application of an immunoassay that uses 2,3,7-trichloro-8-methyldibenzo-p-dioxin (TMDD) as a surrogate standard for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) to sediment and human serum samples. Sample extraction and preparation methods were developed with the aim to establish the simplest, cost-effective and efficient removal of the matrix interferences in the enzyme-linked immunosorbent assay (ELISA). The overall method for sediments is based on a hexane extraction; clean up by a multilayered silica gel column and an activated carbon column; an organic solvent exchange with DMSO-Triton X-100 and ELISA measurement. The gas chromatography-high resolution mass spectrometry (GC-HRMS) validation studies (n = 13) revealed that the method is suitable for the toxic equivalents (TEQ) screening of dioxin in sediments with a method detection limit of about 100pgg(-1) dry sediment with a precision of 13-33% R.S.D. The analysis of a large number of samples originating from different sources would be required to establish more precisely the screening level, as well as the number of false positives and negatives of dioxin TEQ by the immunoassay for sediments. The immunoassay method for sediment analysis offers improvement in speed, sample throughput, and cost in comparison to GC-HRMS. Dioxins were determined in serum samples after a simple liquid-liquid extraction and solvent exchange into DMSO-Triton X-100 without further dilution. The current method (approximate method LOQ of 200pgml(-1) serum) is not sufficiently sensitive for the determination of dioxins in serum to measure acceptable exposure limit.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2004.05.030DOI Listing

Publication Analysis

Top Keywords

serum samples
12
determination dioxins
8
solvent exchange
8
exchange dmso-triton
8
dmso-triton x-100
8
method
6
serum
5
immunochemical determination
4
sediment
4
dioxins sediment
4

Similar Publications

Background: Intestinal transplantation (ITx) represents the only curative option for patients with irreversible intestinal failure. Nevertheless, its rejection rate surpasses that of other solid organ transplants due to the heightened immunological load of the gut. Regulatory T-cells (Tregs) are key players in the induction and maintenance of peripheral tolerance, suggesting their potential involvement in modulating host vs.

View Article and Find Full Text PDF

Rift Valley fever (RVF) is an important viral zoonotic disease that not only affects ruminants but causes serious morbidity and mortality in humans. In humans, its symptoms range from mild flu-like signs to a severe form such as retinal damage, meningoencephalitis to haemorrhagic fever. In this study, 202 human serum samples were collected from central and western parts of Zambia and tested for RVF-specific antibodies using a commercially available ELISA kit.

View Article and Find Full Text PDF

Aim: To study the effect and elucidate the underlying mechanisms of VDAC1-ΔC on autophagy in renal tubular epithelial cells injured by hypoxia/reoxygenation.

Methods: C57/BL6 mice were randomly divided into groups: sham operation group, IRI 1d group and IRI 2d group. The inner canthal blood of mice was collected to detect the levels of serum creatinine and urea nitrogen and kidney tissues were sampled, and sections were stained with Periodic acid-Schiff for morphological evaluation.

View Article and Find Full Text PDF

HMGB1 assists the predictive value of tumor PD-L1 expression for the efficacy of anti-PD-1/PD-L1 antibody in NSCLC.

Cancer Chemother Pharmacol

January 2025

Department of Molecular and Internal Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.

Background: The expression of anti-programmed cell death ligand-1 (PD-L1) in tumors is widely used as a biomarker to predict the therapeutic efficacy of anti-programmed cell death-1(PD-1)/PD-L1 antibodies. However, the predictive accuracy of this method is limited. High-mobility group box 1 (HMGB1) is known to modulate cancer immunity.

View Article and Find Full Text PDF

Pourpose: This study aimed to investigate the seroepidemiological status of Toxoplasma gondii (T. gondii) infection in Multiple Sclerosis (MS) patients compared to controls.

Methods: The present study included 98 MS patients and 100 controls.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!