A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of orthophosphate and total phosphates (inorganic phosphates plus purine nucleotides) using a bioamperometric flow-injection system made up by a 16-way switching valve. | LitMetric

Orthophosphate and total phosphates (inorganic phosphates plus purine nucleotides) can be determined simultaneously in a novel flow-injection system made up by a 16-way switching valve with two sample loops, acid phosphatase (AcP) immobilized reactor and a delay coil needed to separate two peaks corresponding to two sample portions injected simultaneously. An orthophosphate enzyme electrode with a hybrid membrane of trienzyme film and poly(1,2-diaminobenzene) film was used to selectively detect both the endogenous orthophosphate and orthophosphate generated enzymatically into the AcP immobilized reactor, without any interferences from electroactive species, such as ascorbate and urate. Because two sample portions passed through the flow line with different residence time, two peaks were obtained. The first peak corresponded selectively to orthophosphate and the second peak to the total of inorganic phosphates and purine nucleotides. The maximum currents of both peaks were linearly related to the concentration of orthophosphate and total phosphates (as orthophosphate) in the range 5x10(-7)-8x10(-4) M, respectively; 30 samples per hour can be processed with an R.S.D. <2.5%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0039-9140(03)00128-0DOI Listing

Publication Analysis

Top Keywords

orthophosphate total
12
total phosphates
12
inorganic phosphates
12
phosphates purine
12
purine nucleotides
12
orthophosphate
8
phosphates inorganic
8
flow-injection system
8
system 16-way
8
16-way switching
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!