A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Water-soluble polymers for spectrophotometric and flow injection determination of cobalt with nitroso-R-salt. | LitMetric

The water-soluble polymers poly(ethylenimine), quaternized poly(ethylenimine), and poly-4-vinyl-(N-benzyltrimethyl) ammonium chloride were found to be able to change the kinetics of the reaction of cobalt with nitroso-R-salt and the optical density of the cobalt complex formed. The optimum pH range for the complex formation was a wide range from 1 to 10 and at pH 2 the reaction developed instantly. The calibration graph was linear in the range 0.005-2 mug ml(-1). The effective molar absorptivity coefficient of the complex was equal to (2.8+/-0.08)10(3). A spectrophotometric determination method for cobalt with nitroso-R-salt in the presence of water-soluble polymers (before and after membrane preconcentration) and a colorimetric flow injection method were developed. For the flow injection-based spectrophotometric determination, the calibration graph was linear in the concentration range of 0-4.0 mug ml(-1) cobalt with a regression coefficient of 0.9992. The relative standard deviation (R.S.D.) for the determination of 1.0 mug ml(-1) cobalt was 0.9% (ten replicate injections), and at all concentration measured, the R.S.D. of the data was below 5.0%. The proposed FI procedure was applied to river water samples after membrane preconcentration of cobalt. The limit of detection was 4 ng ml(-1).

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0039-9140(01)00675-0DOI Listing

Publication Analysis

Top Keywords

water-soluble polymers
12
cobalt nitroso-r-salt
12
flow injection
8
calibration graph
8
graph linear
8
spectrophotometric determination
8
membrane preconcentration
8
ml-1 cobalt
8
cobalt
7
polymers spectrophotometric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!