Studies of speed, resolution, and selectivity have shown that packed column supercritical fluid chromatography (PCSFC) is a viable technique for the isocratic, isothermal and isobaric separation of seven anticonvulsants, viz., phenobarbitone, phenytoin sodium, phethenylate sodium, nitrazepam, clonazepam, carbamazepine, and primidone, and their simultaneous estimation. The drugs were eluted from a JASCO, RP-C(18) (250 x 4.6 mm) 10 micro packed column with a binary mobile phase of carbon dioxide and methanol, using ibuprofen as the internal standard. The effect of pressure, temperature, modifier concentration, and the rate of flow of CO(2) on retention and selectivity of all the analytes were studied and the parameters optimised. Without methanol in the mobile phase none of the solutes eluted. Changing modifier concentration was the most effective physical parameter for changing retention and selectivity. The analytes were detected using a UV detector at 215 nm. An arbitrary mixture of eight components was baseline resolved in approximately 7 min. The study includes a successful attempt at quantification of the drugs. Chromatographic and analytical figures of merit have been listed. The present work holds promise for a possible replacement of HPLC with SFC for the separation and assay of drugs of different families.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0039-9140(98)00341-5DOI Listing

Publication Analysis

Top Keywords

packed column
12
column supercritical
8
supercritical fluid
8
fluid chromatography
8
mobile phase
8
modifier concentration
8
retention selectivity
8
selectivity analytes
8
application packed
4
chromatography simultaneous
4

Similar Publications

Simulation of the performance of pillar array columns using the pore-throat ratio as efficiency descriptor.

J Chromatogr A

January 2025

Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, EH9 3BF, United Kingdom.

Traditional packed beds in chromatography suffer from increased band broadening due to the random nature of packing, leading non-ideal fluid flow and channeling. To address these challenges, pillar array columns have been developed, offering improved performance over random packing thanks to their homogenous fluid profiles. The study aims to i) evaluate fluid dynamics and chromatographic performance across different PAC morphologies, ii) establish the influence of column morphology on performance, and iii) assess the correlation between chromatographic performance and hydrodynamic parameters.

View Article and Find Full Text PDF

Packed columns are commonly used in post-combustion processes to capture CO emissions by providing enhanced contact area between a CO-laden gas and CO-absorbing solvent. To study and optimize solvent-based post-combustion carbon capture systems (CCSs), computational fluid dynamics (CFD) can be used to model the liquid-gas countercurrent flow hydrodynamics in these columns and derive key determinants of CO-capture efficiency. However, the large design space of these systems hinders the application of CFD for design optimization due to its high computational cost.

View Article and Find Full Text PDF

The discharge of chromium(VI) into the environment is becoming a significant global concern. Despite the existence of numerous techniques for chromium(VI) removal, substantial challenges persist in effectively mitigating this issue. Therefore, this study investigates the feasibility of using low-cost basalt rock as an adsorbent for chromium(VI) removal.

View Article and Find Full Text PDF

Development and validation of a rapid and accurate ultra performance liquid chromatography-photodiode array method for concurrent quantification of thirty-two polyphenols in edible fruit of Cordia myxa Linn.

J Chromatogr A

December 2024

Chemical Technology Division, CSIR-Institute of Himalayan Bioresource Technology, Palampur (Himachal Pradesh), 176061, India; Academy of Scientific and Innovative Research, (AcSIR), Ghaziabad, 201002, India. Electronic address:

The aim of current work was to develop a novel, simple, sensitive, and reliable method for screening and quantification of thirty-two polyphenol compounds from Cordia myxa (C. myxa) using Ultra Performance Liquid Chromatography Photodiode Array detector (UPLC-PDA). With the help of the quaternary solvent manager and a comparison study of seven different columns packed with silica particles that are less than two micron thick (1.

View Article and Find Full Text PDF

Preparation of novel chiral stationary phases based on chiral metal-organic cages enable extensive HPLC enantioseparation.

Anal Chim Acta

February 2025

Key Laboratory of Molecular Medicine and Biotherapy, School of Life Science, Beijing Institute of Technology, No. 5 Zhongguancun South Street, Beijing, 100081, China. Electronic address:

Background: The metal organic cages (MOCs) are an emerging type of porous material that has attracted considerable research interest due to their unique properties, including good stability and well-defined intrinsic cavities. The chiral MOCs with porous structures have broad application prospects in enantiomeric recognition and separation. However, there are almost no relevant reports on chiral MOCs as chiral stationary phases (CSPs) for enantioseparation by high-performance liquid chromatography (HPLC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!