Detection of apolipoprotein E genotypes by capillary electrophoresis.

Talanta

Department of Pathology, National University of Singapore, Kent Ridge, Singapore 119260, Singapore; Department of Laboratory Medicine, National University Hospital, Singapore 119074, Singapore.

Published: February 1998

The apolipoprotein E (apo-E) genotype of an individual is of significant relevance in the associated risk of developing cardiovascular disease and late-onset Alzheimer's disease. Detection of the six common apo-E genotypes is based on the restriction fragment length polymorphisms (RFLPs) arising from the abolition or creation of HhaI restriction sites within an amplified target DNA sequence of the apo-E gene. Genomic DNA was extracted from leukocytes, a 230 bp target sequence within the apo-E gene was amplified by polymerase chain reaction (PCR) and digested with HhaI, and the restricted DNA fragments separated by capillary electrophoresis (CE). This was performed on the BioFocustrade mark 3000 automated CE system equipped with an experimental laser-induced fluorescence (LIF) detector (Bio-Rad Laboratories, Hercules, CA), using capillaries (27 cm length, 75 mum i.d.) coated internally with polyaminoacryloylethoxyethanol. The analysis buffer (2xTris borate-EDTA, pH 8.3) was supplemented with a proprietary sieving polymer and 0.05 muM thiazole orange six. Samples were injected electrophoretically. Separations were carried out at 40 degrees C under constant voltage, and the emitted fluorescence detected at 515 nm. Restriction fragment lengths of the cleaved PCR products were estimated from the migration times, with a 20/100 bp ladder (Bio-Rad Laboratories 20/100 bp molecular ruler) serving as reference. Six different reproducible patterns were obtained for the six common apo-E genotypes, with good resolution of the component restriction fragments. The calculated sizes of the separated peaks closely corresponded with the predicted restricted fragment lengths for each specific genotype. We believe this is the first published report demonstrating the feasibility of automating the post-PCR detection of the apo-E RFLPs(2). This methodology overcomes the most labour-intensive step in apo-E genotyping, thus making it amenable to routine clinical application.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0039-9140(97)00286-5DOI Listing

Publication Analysis

Top Keywords

capillary electrophoresis
8
common apo-e
8
apo-e genotypes
8
restriction fragment
8
sequence apo-e
8
apo-e gene
8
bio-rad laboratories
8
fragment lengths
8
apo-e
7
detection apolipoprotein
4

Similar Publications

Background: The Vero cell rabies vaccine is currently the most widely used human rabies vaccine. However, owing to the presence of residual host cell DNA (HCD) in the final product and the potential tumorigenicity of the DNA of high-passage Vero cells, the WHO not only sets a limit on the number of times cells used in production can be passaged, but also imposes strict requirements on the amount of residual HCD in the final vaccine product.

Objectives: To systematically reduce the HCD level in the final vaccine product, multiple purification steps are included in the vaccine production process.

View Article and Find Full Text PDF

Background: Gadolinium-based contrast agents (GBCA) are widely used in magnetic resonance imaging (MRI) to enhance image contrast by interacting with water molecules, thus improving diagnostic capabilities. However, understanding the residual accumulation of GBCA in tissues after administration remains an area of active research. This highlights the need for advanced analytical techniques capable of investigating interactions between GBCAs and biopolymers, such as type I collagen, which are abundant in the body.

View Article and Find Full Text PDF

This paper introduces a novel contactless single-chip detector that utilizes impedance-to-digital conversion technology to measure impedance in the microfluidic channel or capillary format analytical device. The detector is designed to operate similarly to capacitively coupled contactless conductivity detectors for capillary electrophoresis or chromatography but with the added capability of performing frequency sweeps up to 200 kHz. At each recorded data point, impedance and phase-shift data can be extracted, which can be used to generate impedance versus frequency plots, or phase-shift versus frequency plots.

View Article and Find Full Text PDF

Progresses and Prospects on Glucosinolate Detection in Cruciferous Plants.

Foods

December 2024

State Key Laboratory of Vegetable Biobreeding, Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Beijing 100081, China.

This review provides a comprehensive summary of the latest international research on detection methods for glucosinolates in cruciferous plants. This article examines various analytical techniques, including high-performance liquid chromatography (HPLC), liquid chromatography-mass spectrometry (LC-MS), enzyme-linked immunosorbent assay (ELISA), and capillary electrophoresis (CE), while highlighting their respective advantages and limitations. Additionally, this review delves into recent advancements in sample preparation, extraction, and quantification methods, offering valuable insights into the accurate and efficient determination of glucosinolate content across diverse plant materials.

View Article and Find Full Text PDF

Treatment of severely injured patients represents a major challenge, in part due to the unpredictable risk of major adverse events, including death. Preemptive personalized treatment aimed at preventing these events is a crucial objective of patient management; however, the currently available scoring systems provide only moderate guidance. Biomarkers from proteomics/peptidomics studies hold promise for improving the current situation, ultimately enabling precision medicine based on individual molecular profiles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!