The relative advantages and disadvantages of transabdominal (TA) and transcervical (TC) chorionic villus sampling (CVS) in terms of fetal risks and efficacy were evaluated in a clinical trial conducted on 1194 women randomized at 7-12 weeks' gestation. The results of the study indicate that, if any, the relative risk of fetal loss following either procedure is less than double that of the alternative technique when performed by a skilled operator. Overall, the fetal loss rate (spontaneous abortions following randomization, terminations of pregnancy, and perinatal deaths) is 16.5 and 15.5 per cent, respectively, among women allocated to TA- and TC-CVS. The two procedures are equally effective, although TA-CVS is associated with a significantly lower rate of repeat device insertions; on the other hand, a higher weight of chorionic tissue is obtained, on average, with TC-CVS. Bleeding is more common following TC-CVS, while peritoneal reaction developed only after TA-CVS. No diagnostic problems specifically related to one sampling technique were identified.