A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sensitive apparatus for obtaining freezing curves Purity of 4-aminopyridine. | LitMetric

Sensitive apparatus for obtaining freezing curves Purity of 4-aminopyridine.

Talanta

Ames Laboratory, United States Atomic Energy Commission and Department of Physics, Iowa State University, Ames, Iowa, 50010 U.S.A.

Published: August 1975

AI Article Synopsis

  • Freezing curves of highly-purified 4-aminopyridine were recorded using a newly-designed instrument with specialized components for precise temperature control.
  • The setup maintained a constant temperature difference of 0.005 degrees between the crucible and shield, allowing accurate measurement without stirring.
  • Despite issues with gold corrosion from the molten 4-aminopyridine, initial impurities were likely minimal, under the detection limit of 0.001 mole %.

Article Abstract

Freezing curves of highly-purified 4-aminopyridine have been obtained with an instrument of new design employing a gold crucible, a platinum resistance thermometer, electrical heating elements on crucible and heat shield, and accessory electrical control devices such that the temperature difference between crucible and shield could be maintained constant within 0.005 degrees while the temperature of the 4-aminopyridine and crucible dropped through the freezing range. No stirring was used. Methods were devised for handling the data as the derivative of temperature with respect to time and of correcting the freezing curve for the heat capacity of the crucible and charge. Although interpretation of the freezing curves obtained on the 4-aminopyridine was confused by attack on the gold by the molten 4-aminopyridine, the initial impurity in the 4-aminopyridine was probably less than the detection limit, 0.001 mole %.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0039-9140(75)80003-8DOI Listing

Publication Analysis

Top Keywords

freezing curves
12
4-aminopyridine
6
freezing
5
crucible
5
sensitive apparatus
4
apparatus obtaining
4
obtaining freezing
4
curves purity
4
purity 4-aminopyridine
4
4-aminopyridine freezing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!