A new method for the determination of illicit and abused drugs in blood by capillary zone electrophoresis-electrospray ionization-time-of-flight mass spectrometry is proposed, in view of its application in clinical and forensic toxicology. The analytes (methamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethamphetamine, methadone, cocaine, morphine, codeine, 6-acethylmorphine, benzoylecgonine) were separated with capillary zone electrophoresis by applying 15 kV within 25 min, in an uncoated fused-silica capillary (75 microm x 100 cm) using a 25 mM ammonium formate electrolyte solution (pH 9.5). The capillary electropherograph was coupled to time-of-flight mass spectrometry through an orthogonal electrospray ionization source, with a coaxial sheath liquid interface. The sheath liquid was composed of isopropanol-water (1:1 v/v) containing 0.5% formic acid delivered at 4 microL/min. Forensic drugs were identified by exact mass determination (mass accuracy typically < or =5 ppm) and by matching of the isotopic pattern. Under optimized conditions, linearity was assessed in the range 10-2000 ng/mL, with correlation coefficients between 0.9744 and 0.9982 for all the analytes. LODs were in the range of 2-10 ng/mL (S/N > or =3) and LOQs of 10-30 ng/mL. The CVs (tested at 40 and 800 ng/mL in biological matrix) were below 2.97% for migration times and below 14.61% for peak area ratios (analyte/internal standard). Blood samples were extracted by using a liquid-liquid extraction procedure and injected under field-amplified sample stacking conditions. The method was successfully applied to real cases.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200800087DOI Listing

Publication Analysis

Top Keywords

capillary zone
12
mass spectrometry
12
zone electrophoresis
8
coupled time-of-flight
8
time-of-flight mass
8
drugs blood
8
sheath liquid
8
capillary
5
mass
5
electrophoresis cze
4

Similar Publications

The development and validation of an accurate, selective, and eco-friendly capillary zone electrophoretic detection (CZE) method has been presented for concurrent measurement of inorganic and organic anions including chloride, sulfate, formic acid, citric acid, acetic acid, phosphate, and glutamic acid in Human Milk Oligosaccharides (HMOs) for the first time. An electrolyte composed of an aqueous solution of benzoic acid, 16.38 mM; l-histidine, 24.

View Article and Find Full Text PDF

Chagas disease (CD), a parasitic infection, may have ocular repercussions in its cardiologic form, since a history of heart disease of other etiologies already has been established as a risk factor for neuropathies and maculopathies. The aim of the present study was to investigate preclinical structural and vascular optic nerve head (ONH) and macular parameters in patients with chronic CD. Nineteen patients with CD and 19 healthy subjects were evaluated with optical coherence tomography, optical coherence tomography angiography, and Laguna ONhE® software.

View Article and Find Full Text PDF

Genotype-phenotype correlation and potential genetic risk in the compound heterozygosity for unstable hemoglobins (UHbs) and α-thalassemia were discussed. Capillary electrophoresis and gene sequencing helped to establish the diagnosis. Hematological analysis showed the following findings: MCV 80.

View Article and Find Full Text PDF

Purpose: To assess the retinal and choroidal microvascular changes in patients with benign essential blepharospasm (BEB) and to investigate the factors that may be effective on microvascularity.

Methods: This study included patients with BEB and healthy controls. All participants underwent a comprehensive examination followed by optical coherence tomography angiography (OCTA).

View Article and Find Full Text PDF

Aim: To compare the macular and optic nerve perfusion and vascular architecture using optical coherence tomography angiography (OCTA) in normal eyes of Egyptian (Caucasians) and South Asian (Asians) volunteers.

Methods: Cross-sectional analytical OCTA study performed on 90 eyes of South Asian (=45) and Egyptians (=45) were analyzed. All participants underwent best-corrected visual acuity test, slit lamp, and fundus examination.

View Article and Find Full Text PDF