Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Use of enzymes in cosmetic products is novel and the safety of these products is not well understood. The safety of a prototype enzyme-containing body moisturizer lotion was tested via measures of skin compatibility and potential to induce protease-specific IgE antibody in a clinical study. Female, atopic subjects (n = 1,100) used body lotion containing 100 ppm protease (Y217L BPN') for 5 consecutive days per month, for 18 months. Regular lotion was used the remaining days of each month. Skin evaluation and skin prick tests (SPT) were conducted every 3 months. Measures of skin hydration were made in a subset of subjects at 3-month intervals: skin biopsies occurred at baseline and at the first 3-month timepoint. Serum from SPT positive subjects was tested for specific IgE in an immunoCAP assay. Clinical evaluation and histopathology showed no skin irritation and increased hydration of the skin over time. Three of 864 subjects completing the study developed IgE antibody to the enzyme: 1 subject after 6 months product use and 2 subjects after 15 months product use. A fourth subject was found with IgE antibody 3 months after study termination. None had allergic symptoms associated with product use. Intermittent exposure to a low level of protease enzyme in a body lotion led to the development of specific IgE antibody in 0.46% of subjects. While this study showed favorable skin compatibility of the protease containing lotion, the occurrence of allergic antibody to the enzyme was unacceptable for product commercialization.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/15476910490496249 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!