A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Possible damage to the eye caused by light from ophthalmologic equipment]. | LitMetric

[Possible damage to the eye caused by light from ophthalmologic equipment].

Klin Monbl Augenheilkd

Abteilung für Medizinische Optik, Universitäts-Augenklinik Hamburg.

Published: June 1991

Motivated by numerous findings of the damaging effect of intense light levels on the fundus we measured the spectral radiation of several ophthalmic illuminations and used it to calculate from it the spectral retinal irradiance. To evaluate the thermal hazard, we calculated the resulting temperature rise at the fundus. A measure for biological damage is the percentage of denaturated molecules, which is related to the temperature rise and its duration (essentially identical to the duration of illumination) by the so-called Arrhenius-integral. We used this measure to compare any illumination with experimentally evaluated threshold values for thermal damage. To evaluate the photochemical hazard we compared the spectral retinal irradiance with threshold values for photochemical induced lesions. Furthermore the illuminations were correlated with safety-guidelines likewise distinguishing between thermal and photochemical hazard. Under adverse conditions operation microscopes can present a thermal hazard to the patient's eye. Other ophthalmic illuminations are of less concern in this respect. A similar estimation applies to hazard from photochemical effects. The photochemical hazard can be diminished essentially by reducing the short-wavelength bluelight. Qualitatively, maximal permissible exposures according to safety guidelines are consistent with our thermal calculations as well as with photochemical hazard evaluation by comparing spectral retinal light levels with threshold irradiance for photochemical induced lesions. However, since quantitatively safety guidelines estimate the thermal hazard very conservatively, many common ophthalmic illuminations exceed the exposure limits, in some cases even drastically.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2008-1046049DOI Listing

Publication Analysis

Top Keywords

photochemical hazard
16
ophthalmic illuminations
12
spectral retinal
12
thermal hazard
12
light levels
8
retinal irradiance
8
hazard
8
temperature rise
8
threshold values
8
photochemical induced
8