A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Monitoring of ultrasonography in artificial vascular graft for arteriovenous fistula]. | LitMetric

[Monitoring of ultrasonography in artificial vascular graft for arteriovenous fistula].

Zhonghua Wai Ke Za Zhi

Department of Ultrasound, Beijing Hospital, Beijing 100730, China.

Published: May 2008

Objective: To evaluate the monitoring of ultrasonography in artificial vascular graft for arteriovenous fistula and its complications in patients with chronic renal failure.

Methods: Eighteen cases of artificial vascular graft arteriovenous fistula after four to six weeks were enrolled. The diameter, the peak velocity and blood flow were examined in arterial fistula. And the artificial vascular diameter, the peak velocity and blood flow of artificial vessels next to artery were all examined and analyzed. And the patients with symptoms in the upper extremity were tested by ultrasound.

Results: Intravascular blood showed good filling in fistula and artificial blood vessels in four to six weeks after artificial vascular graft for arteriovenous fistula by color doppler ultrasonography. The arterial fistula diameter, the peak velocity and blood flow were (3.61 +/- 0.68) mm and (298.56 +/- 93.42) cm/s and (583.62 +/- 216.77) ml/min. Artificial vascular diameter in (4.47 +/- 0.61) mm, the peak velocity and blood flow were (219.37 +/- 68.42) cm/s and (325.23 +/- 117.12) ml/min in the artificial blood vessels next to artery. Seven patients with upper extremity discomfort were examined by ultrasonography. One case was serum swollen. Three cases were thrombosis in artificial vessels. One case was pseudoaneurysm. Two cases were edema.

Conclusions: Ultrasonography plays a significant clinic role in testing artificial vascular graft for arteriovenous fistula and its complications.

Download full-text PDF

Source

Publication Analysis

Top Keywords

artificial vascular
28
vascular graft
20
graft arteriovenous
20
arteriovenous fistula
16
peak velocity
16
velocity blood
16
blood flow
16
diameter peak
12
artificial
11
ultrasonography artificial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!