A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improving countershock success prediction during cardiopulmonary resuscitation using ventricular fibrillation features from higher ECG frequency bands. | LitMetric

Background: Countershock outcome prediction using ventricular fibrillation (VF) feature analysis needs undisturbed electrocardiogram (ECG) signals and therefore requires interruption of cardiopulmonary resuscitation (CPR). Features that originate from higher frequency bands of the VF power spectrum may be less affected by CPR artefacts and as such reduce cumulative hands-off intervals.

Materials And Methods: From 192 patients with in-hospital and out-of-hospital cardiac arrest, four countershock outcome prediction features (peak-peak amplitude, mean slope, median slope, power spectrum analysis) were analysed in 550 short time ECG records, each including a CPR corrupted and a subsequent undisturbed sequence. ECG features calculated from the main frequency band (0-26Hz) and from bandpass-filtered subbands (>10-26Hz) were compared using the similarity level method and differences in shock advice numbers.

Results: The feature similarity between ECG periods with and without CPR artefacts was higher in bandpass-filtered (Sim=0.79, 0.8, 0.78, 0.66) than in unfiltered ECG traces (Sim=0.58, 0.69, 0.68, 0.47). For the features evaluated, the difference in number of shock advices between subsequent traces with and without CPR artefact was significantly reduced using VF analysis from higher frequency bands.

Conclusion: The accuracy of shock outcome prediction during CPR could be increased by using filtered ECG features from higher ECG subbands instead of features derived from the main ECG spectrum.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resuscitation.2008.07.024DOI Listing

Publication Analysis

Top Keywords

outcome prediction
12
ecg
9
cardiopulmonary resuscitation
8
ventricular fibrillation
8
features higher
8
higher ecg
8
frequency bands
8
countershock outcome
8
higher frequency
8
power spectrum
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!