A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility and accuracy of duplex ultrasonography in evaluating in-stent restenosis after carotid stenting. | LitMetric

Background: Stents alter flow velocities after carotid artery stenting (CAS). To identify criteria for in-stent restenosis (ISR), velocities obtained by duplex ultrasonography (DU) after CAS were analyzed.

Methods: Carotid angiography and DU were performed after 129 CAS procedures. The 2 x 2 table method and receiver operating characteristic curves were used to assess the ability of DU to detect ISR.

Results: The median follow-up period was 21.2 months (interquartile range 14-32 months). Overall, 6 patients (4.7%) had significant ISR by angiography. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the validated criteria for nonstented arteries were 100%, 85%, 25%, and 100%, respectively, to determine ISR. Newly validated criteria revealed optimal detection of ISR, with 100% sensitivity, 99% specificity, PPV of 66%, and NPV of 100%. Patients with abnormal findings on initial DU revealed increased velocities by >80% when ISR occurred.

Conclusions: DU can accurately detect ISR after CAS, but velocity criteria require modification and validation at each vascular laboratory. For patients with abnormal findings on initial DU, significant changes in velocities suggest ISR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjsurg.2008.07.008DOI Listing

Publication Analysis

Top Keywords

duplex ultrasonography
8
in-stent restenosis
8
validated criteria
8
patients abnormal
8
abnormal findings
8
findings initial
8
isr
7
utility accuracy
4
accuracy duplex
4
ultrasonography evaluating
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!