A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of an automated immunoglobulin G-only cytomegalovirus (CMV) antibody screening assay and an assessment of the risk of transfusion transmitted CMV from seronegative blood. | LitMetric

Background: Cytomegalovirus (CMV) antibody donor screening assays have predominantly included both immunoglobulin G (IgG) and immunoglobulin M (IgM) detection. However, since in the majority of cases both CMV IgG and IgM are detected concomitantly during early seroconversion, CMV assays based only on IgG are now widely applied for donor screening.

Study Design And Methods: The performance of an automated microparticle CMV IgG assay (Abbott AxSYM CMV IgG microparticle enzyme immunoassay [MEIA]) was compared with an established total antibody blood screening assay (Abbott CMV Total AB EIA). Sensitivity and specificity were assessed using 5050 random blood donors and 13 seroconversion panels. A risk analysis was undertaken to estimate the residual risk of transfusion-transmitted CMV (TT-CMV) from presumptive seronegative blood components.

Results: The EIA achieved marginally (but not significantly) better resolved sensitivity (100%) than the AxSYM IgG assay (99.93%). The AxSYM IgG resolved specificity (99.34%) was superior to the EIA (96.4%). This superiority was maintained (98.61%) when a modified cutoff was applied to the AxSYM IgG assay to achieve 100 percent resolved sensitivity. The seroconversion sensitivities of the EIA and the AxSYM IgG were equivalent, detecting the same bleed as positive in the majority of the seroconversion panels tested. The median TT-CMV residual risk estimate for the two assays was approximately 1 in 66,000 (range, 42,000-165,000).

Conclusion: The AxSYM IgG MEIA is suitable for blood donor screening and was optimized by applying a modified cutoff of 9 AU per mL. The modeling predicts that implementing the AxSYM IgG assay would not negatively impact the already very low risk of TT-CMV associated with seronegative blood components in Australia.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1537-2995.2008.01932.xDOI Listing

Publication Analysis

Top Keywords

axsym igg
24
igg assay
16
seronegative blood
12
cmv igg
12
igg
11
cmv
9
cytomegalovirus cmv
8
cmv antibody
8
screening assay
8
donor screening
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!