Au-Ag template stripped pattern for scanning probe investigations of DNA arrays produced by dip pen nanolithography.

Langmuir

Dipartimento di Chimica, Materiali e Ingegneria Chimica "G. Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano, Italy.

Published: November 2008

We report on DNA arrays produced by dip pen nanolithography (DPN) on a novel Au-Ag micropatterned template stripped surface. DNA arrays have been investigated by atomic force microscopy (AFM) and scanning tunneling microscopy (STM) showing that the patterned template stripped substrate enables easy retrieval of the DPN-functionalized zone with a standard optical microscope permitting multi-instrument and multitechnique local detection and analysis. Moreover the smooth surface of the Au squares ( approximately 5-10 A roughness) allows AFM/STM to be sensitive to the hybridization of the oligonucleotide array with label-free target DNA. Our Au-Ag substrates, combining the retrieving capabilities of the patterned surface with the smoothness of the template stripped technique, are candidates for the investigation of DPN nanostructures and for the development of label-free detection methods for DNA nanoarrays based on the use of scanning probes.

Download full-text PDF

Source
http://dx.doi.org/10.1021/la801903uDOI Listing

Publication Analysis

Top Keywords

template stripped
16
dna arrays
12
arrays produced
8
produced dip
8
dip pen
8
pen nanolithography
8
dna
5
au-ag template
4
stripped
4
stripped pattern
4

Similar Publications

The electroreduction-free stripping analysis of copper (II) ions and the voltammetric detection of nonylphenol and tetracycline based on graphdiyne/carbon nanotubes.

Talanta

December 2024

School of the Environment and Safety Engineering, and Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang, 212013, PR China; Key Laboratory of Monitoring for Heavy Metal Pollutants, Ministry of Ecology and Environment, PR China. Electronic address:

The heavy metal ions (HMI) and π-electronical pollutants are two main types of environmental water contaminants, thus designing a universal sensor for their detection is considerable important. Meanwhile, graphdiyne (GDY) as a star material exhibits many unique advantages, especially superior adsorption and self-reducing property to HMI as well as great affinity to π-electron targets. Herein, by low-cost utilizing carbon nanotubes (CNTs) as the template dedicated to improve the conductivity and dispersibility of GDY, a multifunctional nanohybrid GDY/CNTs was prepared and then revealed successfully as a universal electrochemical sensing material for the HMI and π-electronical pollutants by adopting three models: (a) based on the in-situ adsorption and self-reduction capabilities of GDY towards HMI, an innovative electroreduction-free stripping voltammetry (FSV) sensing strategy was proposed for HMI detection via adopting Cu as a representative, which can effectively avoid the electroreduction process compared with the common anodic stripping voltammetry method; (b) by selecting nonylphenol (NP) and tetracycline (TC) as two representative targets, the sensing performances of GDY/CNTs for the π-electronical pollutants were also confirmed.

View Article and Find Full Text PDF

Curcumin-Based Molecularly Imprinted Polymer Electropolymerized on Single-Use Graphite Electrode for Dipyridamole Analysis.

Molecules

September 2024

Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Avenue 90-92, District 5, 050663 Bucharest, Romania.

Article Synopsis
  • A new disposable electrochemical sensor was developed for detecting dipyridamole (DIP) using a molecularly imprinted polymer (MIP) on a pencil graphite electrode (PGE) with curcumin as a key component.
  • Optimization of various parameters such as pH and monomer-template ratio was crucial for effective MIP formation, allowing for precise analysis of DIP's voltammetric behavior.
  • The sensor achieved its best performance under specific conditions, successfully measuring DIP concentrations in pharmaceutical and water samples, with detection limits of 1.47 × 10 mol/L for differential pulse voltammetry (DPV) and 3.96 × 10 mol/L for adsorptive stripping differential pulse voltammetry
View Article and Find Full Text PDF

Nanoporous Gold-Modified Screen-Printed Electrodes for the Simultaneous Determination of Pb and Cu in Water.

Sensors (Basel)

September 2024

Human Phenome Institute, State Key Laboratory of Genetic Engineering, Fudan University, Shanghai 200438, China.

In this study, nanoporous gold (NPG) was deposited on a screen-printed carbon electrode (SPCE) by the dynamic hydrogen bubble template (DHBT) method to prepare an electrochemical sensor for the simultaneous determination of Pb and Cu by square wave anodic stripping voltammetry (SWASV). The electrodeposition potential and electrodeposition time for NPG/SPCE preparation were investigated thoroughly. Scanning electron microscopy (SEM) and energy-dispersive X-ray diffraction (EDX) analysis confirmed successful fabrication of the NPG-modified electrode.

View Article and Find Full Text PDF

Automated registration-based skull stripping procedure for feline neuroimaging.

Neuroimage

October 2024

Integrated Program in Neuroscience, McGill University, Montreal, Quebec, Canada; Department of Physiology, McGill University, Montreal, Quebec, Canada. Electronic address:

Skull stripping is a fundamental preprocessing step in modern neuroimaging analyses that consists of removing non-brain voxels from structural images. When performed entirely manually, this laborious step can be rate-limiting for analyses, with the potential to influence the population size chosen. This emphasizes the need for a fully- or semi-automated masking procedure to decrease man-hours without an associated decline in accuracy.

View Article and Find Full Text PDF
Article Synopsis
  • CoO is a P-type semiconductor known for its electrical conductivity, low cost, and safety, and it shows promise for detecting heavy metals like Pb and Cu in water.
  • The study presents a method for creating CoO materials from metal-organic frameworks (MOFs), revealing that one specific variant, CoO-1, has a unique microsphere structure that significantly enhances its sensitivity to these metals.
  • CoO-1/GCE exhibits strong electrochemical properties with a detection range of 0.5-1.5 μM for Pb and Cu, showcasing its potential as an effective sensor while also demonstrating stability and resistance to interference.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!