A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Beating-heart coronary artery bypass grafting using a miniaturized extracorporeal circulation system. | LitMetric

Background: Experience with miniaturized coronary artery bypass (CAB) systems in coronary artery bypass graft (CABG) surgery on the beating heart is limited. We used a relatively new miniaturized cardiopulmonary bypass (CPB) system, which we termed assisted CAB (ACAB), to perform CABG on the beating heart in 110 patients, and we analyzed clinical outcomes in this patient group.

Methods: Between January 2004 and September 2006, we used ACAB to perform CABG on the beating heart in 110 patients. The mean patient age was 73 +/- 8.1 years. The ACAB system uses a small prime volume of only 500 mL, and the circuit is shorter than that used in conventional CPB. In addition, the tubing and oxygenator systems were surface-coated with phosphorylcholine. The initial heparin dose was 150 IU/kg, with a target activated clotting time of >250 seconds. With this management, none of the patients experienced system thrombosis. We did not use cardioplegia or aortic crossclamping and did not routinely retransfuse cardiotomy blood. Observational data for the 110 patients were analyzed.

Results: The mean number of anastomoses performed was 2.67. The rate of perioperative infarction was 1.8% (2 patients). Perioperative mortality was 7% (8 patients). The mean EuroSCORE for all patients was 6.4 +/- 4, whereas it was 13.75 +/- 6.18 for the patients who died. Mean CPB time was 64.96 +/- 16.66 minutes.

Conclusion: In our experience, beating heart CABG supported by a miniaturized CPB is a safe procedure with acceptable perioperative results.

Download full-text PDF

Source
http://dx.doi.org/10.1532/HSF98.20081024DOI Listing

Publication Analysis

Top Keywords

beating heart
16
coronary artery
12
artery bypass
12
110 patients
12
acab perform
8
perform cabg
8
cabg beating
8
heart 110
8
patients
8
beating-heart coronary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!