Electrochemical behavior and determination of rutin on a pyridinium-based ionic liquid modified carbon paste electrode.

J Pharm Biomed Anal

Key Laboratory of Eco-Chemical Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, China.

Published: December 2008

In this paper the electrochemical behavior of rutin on a pyridinium-typed ionic liquid modified carbon paste electrode (IL-CPE) was investigated and further used for rutin sample determination. The IL-CPE showed strong electrocatalytic effects to the oxidation of rutin. In phosphate buffer solution (PBS, pH 2.5; 0.1 M) a pair of well-defined cyclic voltammetric redox peaks of rutin appeared with the redox peak located at 512mV (Epa) and 448mV (Epc) (vs. SCE), respectively. The redox peak current was increased about 27.5 times more than that on traditional carbon paste electrode (CPE). The electrochemical parameters of rutin on the IL-CPE were calculated with the results of the charge transfer coefficient (alpha), the number of electron transfer (n) and the electrode reaction rate constant (k(s)) as 0.53, 1.80 and 2.39s(-1), respectively. The cathodic peak currents increased linearly with the concentration of rutin in the range from 5.0x10(-7) to 1.0x10(-4)M with the detection limit as 3.58x10(-7)M (3sigma). The relative standard deviation (RSD) of 10 successive detection of 5.0x10(-5)M rutin was 4.2%. The method was successfully applied to the determination of rutin content in tablets samples with good recovery. The modified electrode showed good stability and reproducibility without the influence of the coexisting substances.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2008.09.014DOI Listing

Publication Analysis

Top Keywords

carbon paste
12
paste electrode
12
rutin
9
electrochemical behavior
8
determination rutin
8
ionic liquid
8
liquid modified
8
modified carbon
8
redox peak
8
electrode
5

Similar Publications

Background: The buildup of methylparaben (MP), a broad-spectrum antimicrobial preservative with endocrine-disrupting properties, in environmental sources, especially aquatic systems, has become a significant concern due to its adverse health effects, including allergic reactions, promoting the risk of developing cancer, and inducing reproductive disorders. Hence, introducing inexpensive and easy-to-use monitoring devices for rapid, selective, and sensitive detection and quantification of MP is highly desirable. In this context, electrochemical platforms have proven to be attractive options due to their remarkable features, such as ease of fabrication and use, short response time, and acceptable sensitivity, accuracy, and selectivity.

View Article and Find Full Text PDF

Tirofiban hydrochloride is used to inhibit platelet aggregation, which has a significant impact on the treatment of congestive heart failure the most common cause of death according to WHO. Therefore, its quantification in pharmaceutical dosage form is critical. In this work, an electrochemical method for the determination of tirofiban HCl in pharmaceutical dosage form was developed and validated.

View Article and Find Full Text PDF

The antimalarial hydroxychloroquine (HCQ) has considered for the treatment of systemic lupus erythematosus. Moreover, HCQ has been used as a drug to treat Coronavirus disease (COVID-19). In this work, nitrogen doped porous reduced graphene oxide (NprGO) has been prepared via environmentally friendly process using Fummaria Parviflora extract.

View Article and Find Full Text PDF

Preparation and Properties of Sulfur-Modified Alite Calcium Sulfoaluminate Cement.

Materials (Basel)

December 2024

State Key Laboratory of Materials-Oriented Chemical Engineering, College of Materials Science and Engineering, Nanjing Tech University, Nanjing 210009, China.

Alite calcium sulfoaluminate (ACSA) cement is an innovative and environmentally friendly cement compared to ordinary Portland cement (OPC). The synthesis and hydration of ACSA clinkers doped with gradient sulfur were investigated. The clinker compositions and hydrated pastes were characterized by X-ray diffraction (XRD), isothermal calorimetry, mercury intrusion porosimetry (MIP), and scanning electron microscopy (SEM) to analyze its mineral contents, hydration products, heat release, pore structure, and microstructure.

View Article and Find Full Text PDF

Fly ash-cement composite backfill slurry, prepared by partially replacing cement with fly ash, has been demonstrated to effectively reduce the mine backfill costs and carbon emissions associated with cement production. However, the use of fly ash often results in insufficient early and medium-term strength of the backfill material. To address the demand for high medium-term strength in backfill materials under continuous mining and backfilling conditions, this study developed a silica fume-fly ash-cement composite backfill slurry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!