Objective: Aortic isthmus (AoI) velocity waveforms are considered powerful indicators of hemodynamic deterioration in intrauterine growth-restricted (IUGR) fetuses. However, technical difficulties in sampling AoI velocity waveforms from the longitudinal aortic arch (LAA) have limited its clinical application thus far. In this study, we tested the possibility of recording AoI velocity waveforms from the 3-vessel (3V) view of the fetal mediastinum and comparing the agreement of these measurements with recordings from the LAA.

Methods: Doppler measurements of the pulsatility index (PI) from the AoI were performed in 70 fetuses (20 IUGR and 50 normally grown) between 20 and 34 weeks' gestation. All measurements were sampled in both the LAA and 3V views by the same investigator. Reliability was evaluated with intraclass correlation coefficients (ICCs), and Bland-Altman plots were generated. The time required to complete the measurements was compared.

Results: A high degree of reliability was observed between PI values obtained from LAA and 3V views in both IUGR and normally grown fetuses (all fetuses: ICC, 0.976; 95% confidence interval [CI], 0.961-0.985; normally grown: ICC, 0.839; 95% CI, 0.731-0.906; IUGR: ICC, 0.954; 95% CI, 0.886-0.982). However, recordings from the 3V view were significantly less time-consuming than those from the LLA view (mean +/- SD, 30.4 +/- 14.2 versus 52.8 +/- 29.4 seconds; P < .0001) and showed higher intraobserver reproducibility.

Conclusions: In IUGR and normally grown fetuses, AoI waveforms can be reliably obtained from the 3V view with higher reproducibility and a shorter recording time.

Download full-text PDF

Source
http://dx.doi.org/10.7863/jum.2008.27.11.1617DOI Listing

Publication Analysis

Top Keywords

velocity waveforms
16
aoi velocity
12
iugr grown
12
3-vessel view
8
aortic isthmus
8
aortic arch
8
laa views
8
grown fetuses
8
fetuses
6
waveforms
5

Similar Publications

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Background:  Clot waveform analysis (CWA) provides a global assessment of hemostasis and may be useful for patients with cirrhosis with complex hemostatic abnormalities. This study aimed to assess the association between prothrombin time (PT-) and activated partial thromboplastin time (aPTT-) based CWA parameters and cirrhosis severity and prospectively evaluate the role of CWA in predicting mortality and acute decompensation (AD) over 1 year.

Methods:  This prospective study included adult patients with cirrhosis between June 2021 and December 2023 at Chulalongkorn University Hospital.

View Article and Find Full Text PDF

Guided wave tomography of pipe bends based on full waveform inversion.

Ultrasonics

January 2025

Department of Civil Engineering and Architecture, Tallinn University of Technology, Ehitajate tee 5, 19086, Tallinn, Estonia. Electronic address:

Pipe bends are recognized as critical areas susceptible to wall thinning, a phenomenon instigated by abrupt changes in the fluid flow direction and velocity. Conventional monitoring techniques for bends typically depend on localized ultrasonic measurements of thickness. While these methods are effective, they can be time-consuming compared to the use of permanently installed transducers, a strategy employed in guided wave tomography (GWT).

View Article and Find Full Text PDF

Background: The pathological hallmark of Ménière's disease is endolymphatic hydrops, which can lead to an increase in basilar membrane stiffness and, consequently, an acceleration of the traveling wave of sound. The cochlear hydrops analysis masking procedure (CHAMP), which is an auditory brainstem response test masked at various frequencies with high-pass noise masking, uses the principle of the traveling wave velocity theory to determine the presence of endolymphatic hydrops.

Purpose: This study aimed to review the previous results of the CHAMP, expound the principles and key indicators, and discuss its clinical significance in diagnosing Ménière's disease.

View Article and Find Full Text PDF

We present the first controlled-environment measurements of the optical path-length change response of telecommunication submarine cables to active seismic and acoustic waves. We perform the comparison among integrated (optical interferometry) and distributed (distributed acoustic sensing, DAS) fibre measurements and ground truth data acquired by 58 geophones, 20 three-axis seismometers and 7 microphones. The comparison between different seismic acquisition methods is an essential step towards full validation and calibration of the data acquired using novel cable-based sensing techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!