A 69-year-old woman presented with unusual electron microscopic findings. The patient was admitted to ascertain the cause of her persistent proteinuria, and kidney biopsy was performed. While light microscopic findings and immunofluorescence study suggested membranous nephropathy, electron microscopic study showed microspheric particles aggregated in the subepithelial space where electron-dense deposits should have existed. While the microspheric particles could have been unusual and rough deposits, detailed study suggested that the particles could be parts of glomerular podocytes, for example foot processes. This unusual finding was considered as being in a unique clinical course of membranous nephropathy, but a variant of glomerulopathy associated with podocytic infolding, proposed by Joh et al. (J Nephrol 49:61-67, 2007), could not be excluded.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10157-008-0089-7DOI Listing

Publication Analysis

Top Keywords

microspheric particles
12
membranous nephropathy
12
aggregated subepithelial
8
nephropathy variant
8
variant glomerulopathy
8
glomerulopathy associated
8
associated podocytic
8
electron microscopic
8
microscopic findings
8
study suggested
8

Similar Publications

A particle counting immunosensor for the sensitive detection of ochratoxin A via click chemistry-mediated signal amplification.

J Hazard Mater

January 2025

State Key Laboratory of Marine Food Processing and Safety Control, Dalian Polytechnic University, Dalian, Liaoning 116034, PR China. Electronic address:

The existence of ochratoxin A (OTA) in agricultural products poses significant threats to human health and environment, underscoring the critical need for its prompt and precise quantification. A particle counting immunosensor for the highly sensitive detection of OTA was presented, employing SiO@CuO nanoparticles to facilitate click chemistry. The quantity of SiO@CuO nanoparticles, and consequently the Cu²⁺ concentration, can be directly altered through the immune response involving OTA.

View Article and Find Full Text PDF

Titanium (Ti)-based materials are favored for hard tissue applications, yet their bioinertness limits their success. This study hypothesizes that functionalizing Ti materials with chitosan nano/microspheres and calcitriol (VD) will enhance their bioactivity by improving cellular activities and mineralization. To test this, chitosan particles were applied uniformly onto Ti surfaces using electrophoretic deposition (EPD) at 20 V for 3 minutes.

View Article and Find Full Text PDF

Timely and accurate detection of trace mycotoxins in agricultural products and food is significant for ensuring food safety and public health. Herein, a deep learning-assisted and entropy-driven catalysis (EDC)-Argonaute powered fluorescence single-particle aptasensing platform was developed for ultrasensitive detection of fumonisin B (FB) using single-stranded DNA modified with biotin and red fluorescence-encoded microspheres as a signal probe and streptavidin-conjugated magnetic beads as separation carriers. The binding of aptamer with FB releases the trigger sequence to mediate EDC cycle to produce numerous 5'-phosphorylated output sequences, which can be used as the guide DNA to activate downstream Argonaute (Ago) for cleaving the signal probe, resulting in increased number of fluorescence microspheres remaining in the final reaction supernatant after magnetic separation.

View Article and Find Full Text PDF

This work explores the enhancement of EMI shielding efficiency of polyurethane (PU) foam by loading multiwall carbon nanotube (MWCNTs)-decorated hollow glass microspheres (HGMs). MWCNT was coated onto the HGM surface by a simple solution casting technique. The coated HGM particles were loaded in PU foams, resulting in an even dispersion of MWCNT in the foam struts, thereby forming an interconnected conductive network in the polymer matrix.

View Article and Find Full Text PDF

As one of the key diagnostic methods for detecting biomarkers and antigen-antibody interactions, the luminescent oxygen channel immunoassay (LOCI) has been widely applied in bioanalysis and other fields. In the context of LOCI, the performance of the prepared donor polystyrene (PS) microspheres significantly impacts the detection signal values. In this study, an attempt was made to synthesize PS microspheres via one-step polymerization of styrene with an amphiphilic monomer (PEOOH), followed by swelling the silicon phthalocyanine photosensitizer into the PS microspheres, resulting in the functionalization of the PS microspheres with polyethylene glycol segments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!