A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Arm raising at exposure-controlled multidetector trauma CT of thoracoabdominal region: higher image quality, lower radiation dose. | LitMetric

Purpose: To evaluate the effect of arm position on image quality and effective radiation dose in an automatic exposure-controlled (AEC) multidetector thoracoabdominal computed tomography (CT) protocol in trauma patients.

Materials And Methods: This retrospective study of the data of 177 trauma patients (117 male; median age, 39 years) was approved by the institutional ethics board, with informed patient consent waived. Patients underwent scanning by using an AEC 16-detector thoracoabdominal CT protocol in which both arms were raised above the shoulder region (standard-position group, 132 patients), one arm was raised and the other was down (one-arm group, 27 patients), or both arms were down (two-arm group, 18 patients). Objective and subjective image quality was assessed. Individual effective radiation dose was calculated from the effective tube current-time product per exposed section. For this purpose, section location-dependent conversion factors were derived by using a CT dosimetry calculator. The effect of arm position on effective dose was quantified by using linear regression analysis with correction for patient volume and attenuation.

Results: Compared with the image quality in the standard-position group, the image quality in the one- and two-arm groups was decreased but within acceptable diagnostic limits. The median corrected effective dose in the standard-position group was 18.6 mSv; the dose in the one-arm group was 18% (95% confidence interval: 11%, 25%) higher than this, and that in the two-arm group was 45% (95% confidence interval: 34%, 57%) higher.

Conclusion: Omitting arm raising results in lower but acceptable image quality and a substantially higher effective radiation dose. Hence, effort should be made to position the arms above the shoulder when scanning trauma patients. Clinical trial registration no. NCT00228111.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2492080169DOI Listing

Publication Analysis

Top Keywords

image quality
24
radiation dose
16
effective radiation
12
standard-position group
12
arm raising
8
arm position
8
trauma patients
8
one-arm group
8
group patients
8
two-arm group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!