A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of biodegradable drug releasing polymeric cardiovascular stents and in vitro evaluation. | LitMetric

Development of biodegradable drug releasing polymeric cardiovascular stents and in vitro evaluation.

J Microencapsul

Faculty of Pharmacy, Department of Pharmaceutical Technology, Hacettepe University, Sihhiye-Ankara, Turkey.

Published: September 2009

Prednisolone acetate (PA) is insoluble in water and was chosen as a model drug for its anti-inflammatory/anti-proliferative functions. PA is incorporated into the film-based polymeric biodegradable stents to provide controlled local release of the drug during the mechanical support phase. Stent formulations were 3 mm in diameter with lengths of 150 mm. The polymer wall thickness was 145.0 +/- 4.0 microm for microsphere-containing PLGA 75 : 25 stents. The ATR-FTIR spectra showed biodegradable stent surfaces were free of drug and microspheres. Incorporation of PA into the stents increased the surface area when compared to empty and microsphere-incorporated stents. PA release from the stents containing chitosan microspheres was slower than the PA-only incorporated stents. The drug release from the stents coated with microsphere-containing PLGA 75 : 25 solutions was determined to be the slowest one (19.1% cumulative PA released in 32 days). The stents formulated with PLGA 75 : 25 polymers were considered to be more promising due to their suitable mechanical properties and controlled release of the drug.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02652040802465792DOI Listing

Publication Analysis

Top Keywords

stents
9
release drug
8
microsphere-containing plga
8
release stents
8
drug
6
development biodegradable
4
biodegradable drug
4
drug releasing
4
releasing polymeric
4
polymeric cardiovascular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!