The mere intraocular pressure (IOP) measurement and the visual field (VF) examination do not allow early primary open-angle glaucoma (POAG) diagnosis. At present, the morphological and morphometric analysis of the optic disk is considered very important for an early diagnosis and follow-up of the disease. The recent introduction of laser systems equipped with new polarimetry techniques (GDx) and confocal tomography (HRT) allows an objective, quantitative, and reproducible evaluation of the morphometry and morphology of the optic disk and retinal nerve fiber layer (RNFL). The GDx, scanning laser polarimetry, studies the RNFL. The HRT, confocal scanning laser tomography, examines several optic disk and peripapillar area parameters. These devices allow obtaining objective and quantitative data concerning RNFL and optic nerve head. They represent complementary and important examinations in case of uncertain POAG diagnosis. The correct evaluation of the parameters studied by these techniques and the knowledge of the instruments' limits are needed for an adequate interpretation of the results obtained.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0079-6123(08)01109-6 | DOI Listing |
J Phys Chem A
January 2025
Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, United States.
We present direct frequency comb cavity ring-down spectroscopy with Vernier filtering as a straightforward approach to sensitive and multiplexed trace gas detection. The high finesse cavity acts both to extend the interaction length with the sample and as a spectral filter, alleviating the need for dispersive elements or an interferometer. In this demonstration, a free running interband cascade laser was used to generate a comb centered at 3.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
January 2025
UMR SayFood 0782, Université Paris-Saclay, INRAE, Palaiseau, AgroParisTech, France.
Assessing the contamination of paper and board (P&B) food packaging materials poses significant challenges due to the sensitivity limits of analytical methods and the low precision of sampling processes. This study aims to enhance the understanding of P&B food packaging contamination by investigating the distribution of contaminants at different scales using a combination of chromatographic and spectroscopic techniques. A total of 36 substances were targeted, including phthalates, photoinitiators, and bisphenol A.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
Faculty of Technical Chemistry, Institute of Chemical Technologies and Analytics, Technische Universität Wien, Vienna 1060, Austria.
Atomic force microscopy-infrared spectroscopy (AFM-IR) is a photothermal scanning probe technique that combines nanoscale spatial resolution with the chemical analysis capability of mid-infrared spectroscopy. Using this hybrid technique, chemical identification down to the single molecule level has been demonstrated. However, the mechanism at the heart of AFM-IR, the transduction of local photothermal heating to cantilever deflection, is still not fully understood.
View Article and Find Full Text PDFJ Funct Biomater
December 2024
Department of Operative Dentistry, School of Dentistry, University of São Paulo, Avenida Professor Lineu Prestes, 2227, São Paulo 05508-000, SP, Brazil.
This study evaluated the color change (ΔE) and penetration depth (PD) of white spot lesions (WSLs) infiltrated with the resin infiltrant (Icon) functionalized with methacrylate epigallocatechin-3-gallate (EGCG). To introduce polymerizable double bonds, EGCG was reacted with methacryloyl chloride (EM). Subsequently, the Icon resin infiltrant (I) was loaded with neat EGCG (IE) or EGCG-methacrylate (IEM) at 2 wt% each.
View Article and Find Full Text PDFJ Imaging
January 2025
Faculty of Information Technology and Communication Sciences, Mathematics Research Centre, Tampere University, Korkeakoulunkatu 1, 33720 Tampere, Finland.
This article describes procedures and thoughts regarding the reconstruction of geometry-given data and its uncertainty. The data are considered as a continuous fuzzy point cloud, instead of a discrete point cloud. Shape fitting is commonly performed by minimizing the discrete Euclidean distance; however, we propose the novel approach of using the expected Mahalanobis distance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!