The sleep state characteristics of infant sleep apnea were studied in 36 twins examined by polygraphy at 40, 44, and 52 weeks after conception. The definition of sleep apnea is dependent upon the length of apnea, sleep state, and post-conceptional age. None of the infants had apnea longer than 20 seconds and apnea of 10 seconds or longer was uncommon. The attack rates for apneas 2 to 4.9 seconds long were highest in REM and lowest in qliet sleep. The attack rates for apneas 5 to 9.9 seconds long were equal in REM and indeterminate and lowest in quiet sleep. The percentage of infants with apnea of 10 seconds or longer at 40 weeks was highest in REM (27%) and indeterminate sleep (42%) and lowest in quiet sleep (12%). At 52 weeks, apnea 10 seconds or longer during REM decreased to 0%. The effect of maturation on apnea varies with sleep state. Over the period from 40 to 52 weeks, quiet sleep apnea was unchanged and indeterminate sleep apnea decreased only between 40 and 44 weeks. Although REM apnea 2 to 4.9 seconds long was unchanged, REM apnea 5 to 9.9 seconds long decreased between 40 and 44 weeks, and REM apnea of 10 seconds or longer decreased from 27% at 40 weeks to 0% at 52 weeks. This suggests that semi-independent apnea turn-on and turn-off mechanism operate during REM sleep. A correlation between brief apneas and the longer apneas was seen only during REM sleep. For all sleep states, there was no correlation between the levels of apnea of 5 seconds or longer at 40, 44, and 52 weeks.
Download full-text PDF |
Source |
---|
J Contemp Dent Pract
October 2024
Department of Prosthodontics, Dr. D.Y. Patil Dental College & Hospital, Dr. D.Y. Patil Vidyapeeth, Pune, Maharashtra, India.
Aim: The current study aimed to assess the oropharyngeal space using cone-beam computed tomography (CBCT) and its effect on airway volume both before and after denture placement.
Materials And Methods: For this investigation, a total of 15 individuals with fully edentulous upper and lower ridges, ranging in age from 40 to 70, were taken into consideration. A recording of the pulmonary function test was made both prior to and following full denture recovery.
J Obstet Gynaecol Res
February 2025
Sleep Center, Kuwamizu Hospital, Kumamoto, Japan.
Background: Pregnancy-related anatomic, physiologic, and hormonal factors can occur at different stages of pregnancy and affect sleep disturbances. The relationship between sleep problems during pregnancy and postpartum depressive symptoms as well as neonatal condition at delivery have not been well described. This study hypothesized that sleep problems are associated with postpartum depressive symptoms and adverse neonatal outcomes at delivery.
View Article and Find Full Text PDFJ Clin Med
January 2025
Cleveland Clinic Lerner College of Medicine, Case Western Reserve University, Cleveland, OH 44106, USA.
Patients on chronic anticoagulation undergoing metabolic surgery represent an increased risk of complications, including both bleeding and thrombotic events, such as deep vein thrombosis (DVT) and pulmonary embolism (PE). The optimal perioperative management of patients who are receiving chronic anticoagulation therapy (CAT) is complex. In the colorectal surgery literature, patients on CAT have a 10% rate of peri-procedural bleeding and a 3% rate of thromboembolism.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Anesthesiology, The Second Affiliated Hospital, The Army Military Medical University, Chongqing, China.
Background: Rapid sequence induction intubation (RSII) is commonly used in emergency surgeries for patients at high risk of aspiration. However, these patients are more susceptible to hypoxemia during the RSII process. High-flow nasal cannula (HFNC) oxygen therapy has emerged as a potential alternative to traditional face mask (FM) ventilation pre- and apneic oxygenation.
View Article and Find Full Text PDFOrthod Craniofac Res
January 2025
Sleep Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
Objectives: This non-randomised clinical study aimed to identify the phenotypic characteristics that distinguish responders from non-responders. Additionally, it sought to establish a predictive model for treatment response to obstructive sleep apnoea (OSA) using mandibular advancement devices (MAD), based on the analysed phenotypic characteristics.
Material And Methods: This study, registered under identifier NCT05596825, prospectively analysed MAD treatment over 6 years using two-piece adjustable appliances according to a standardised protocol.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!