Statement Of Problem: Various implant impression techniques, such as the splint, pick-up, and transfer techniques, have been introduced, and some techniques may be more accurate than others. Also, clinically, some factors, including the angulation or depth of implants, may affect the accuracy of the implant impressions.
Purpose: The purposes of this review were to: (1) investigate the accuracy of published implant impression techniques, and (2) examine the clinical factors affecting implant impression accuracy.
Material And Methods: An electronic search was performed in June 2008 of MEDLINE, EMBASE, and Cochrane Library databases with the key words implant, implants, impression, and impressions. To be included, the study had to investigate the accuracy of implant impressions and be published in an English peer-reviewed journal. In addition, a hand search was performed to enrich the results for the time period from January 1980 to May 2008. After executing the search strategies, 41 articles were selected to be included in the review process.
Results: All of the selected articles were in vitro studies. Of the 17 studies that compared the accuracy between the splint and nonsplint techniques, 7 advocated the splint technique, 3 advocated the nonsplint technique, and 7 reported no difference. Fourteen studies compared the accuracy of pick-up and transfer impression techniques, and 5 showed more accurate impression with the pick-up techniques, 2 with the transfer technique, and 7 showed no difference. The number of implants affected the comparison of the pick-up and splint techniques. Eleven studies compared the accuracy of polyether and vinyl polysiloxane (VPS), and 10 of 11 reported no difference between the 2 materials. Four studies examined the effect of implant angulation on the accuracy of impressions. Two studies reported higher accuracy with straight implants, while the other 2 reported there was no angulation effect.
Conclusions: The review of abutment level or implant level internal connection implants indicated that more studies reported greater accuracy with the splint technique than with the nonsplint technique. For situations in which there were 3 or fewer implants, most studies showed no difference between the pick-up and transfer techniques, whereas for 4 or more implants, more studies showed higher accuracy with the pick-up technique. Polyether and VPS were the recommended materials for the implant impressions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0022-3913(08)60208-5 | DOI Listing |
Virtual Real
December 2024
Department of Computer Science and Software Engineering, Concordia University, Montreal, Québec Canada.
Epilepsy is a neurological disorder characterized by recurring seizures that can cause a wide range of symptoms. Stereo-electroencephalography (SEEG) is a diagnostic procedure where multiple electrodes are stereotactically implanted within predefined brain regions to identify the seizure onset zone, which needs to be surgically removed or disconnected to achieve remission of focal epilepsy. This procedure is complex and challenging due to two main reasons.
View Article and Find Full Text PDFSci Rep
December 2024
Fertility and IVF Unit, Department of Obstetrics and Gynecology, Soroka University Medical Center, Beer Sheva, 151, Israel.
It has long been speculated that the mechanical properties of the human oocyte can be an indicator for oocyte viability. Recent studies have demonstrated that embryo implantation rates, following Intra-Cytoplasmic Sperm Injection (ICSI) procedures, may be increased if the shear modulus value of the oocyte Zona Pellucida (ZP) is taken into consideration during embryo transfer. The shear modulus was determined by an iterative oocyte specific finite element (FE) analysis based on the clinical ICSI data.
View Article and Find Full Text PDFBDJ Open
December 2024
Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, 749000, Vietnam.
Introduction: Guided surgery for immediate anterior implants aims to reduce the time required for aesthetic and functional immediate loading. However, the limited surface area of anterior teeth for guide stabilization may affect the accuracy of implant positioning. This in vitro study evaluated the effect of the number of supporting teeth on the accuracy of immediate implants in the maxillary central incisor region.
View Article and Find Full Text PDFSci Rep
December 2024
Electronic Engineering College, Heilongjiang University, Harbin, 150080, China.
With the rapid development of the semiconductor industry, Hardware Trojans (HT) as a kind of malicious function that can be implanted at will in all processes of integrated circuit design, manufacturing, and deployment have become a great threat in the field of hardware security. Side-channel analysis is widely used in the detection of HT due to its high efficiency, non-contact nature, and accuracy. In this paper, we propose a framework for HT detection based on contrastive learning using power consumption information in unsupervised or weakly supervised scenarios.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Radiology, Yan'an Hospital of Kunming City (Yan'an Hospital Affiliated to Kunming Medical University; Yunnan Cardiovascular Hospital), Kunming, China.
Immediate breast reconstruction provides breast cancer patients with a valuable opportunity to restore breast shape. However, post-reconstruction breast asymmetry remains a common issue that affects patient satisfaction. This study aims to quantify breast asymmetry after surgery using magnetic resonance imaging (MRI) and assess its impact on both breast satisfaction and overall outcome satisfaction, offering scientific evidence to guide improvements in preoperative evaluation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!