The paper is concerned with the results of dose measurements on a uterine phantom under the conditions close to those of the practice of radiotherapy of endometrial cancer patients using the AGAT-B unit. Comparison of experimental and rated dose values made it possible to find points of particular clinical alertness as well as a point of the control of accuracy of dose formation during a radiotherapeutic session.
Download full-text PDF |
Source |
---|
J Biomech Eng
January 2025
State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanical Engineering, Zhejiang University, Hangzhou, 315000, China.
Due to individual differences, accurate identification of tissue elastic parameters is essential for biomechanical modeling in surgical guidance for hepatic venous injections. This paper aims to acquire the absolute Young's modulus of heterogeneous soft tissues during endoscopic surgery with 2D ultrasound images. First, we introduced a force-sensor-less approach that utilizes a pre-calibrated soft patch with a known Young's modulus and its ultrasound images to calculate the external forces exerted by the probe on the tissue.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Joint Department of Physics, The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, London, SM2 5PT, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND.
The exact temporal characteristics of beam delivery affect the efficacy and outcome of ultra-high dose rate (UHDR or "FLASH") radiotherapy, mainly due to the influence of the beam pulse structure on mean dose rate. Single beams may also be delivered in separate treatment sessions to elevate mean dose rate. This paper therefore describes a model for pulse-by-pulse treatment planning and demonstrates its application by making some generic observations of the characteristics of FLASH radiotherapy with photons and protons.
View Article and Find Full Text PDFPurpose: The depth within the body, small diameter, long length, and varying tissue surrounding the spinal cord impose specific considerations when designing radiofrequency coils. The optimal coil configuration for 7 T cervical spinal cord MRI is unknown and, currently, there are very few coil options. The purpose of this work was (1) to establish a quality control protocol for evaluating 7 T cervical spinal cord coils and (2) to use that protocol to evaluate the performance of 4 different coil designs.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Background: Histotripsy is a non-invasive, non-ionizing, non-thermal focused ultrasound technique. High amplitude short acoustic pulses converge to create high negative pressures that cavitate endogenous gas into a bubble cloud leading to mechanical tissue destruction. In the United States, histotripsy is approved to treat liver tumors under diagnostic ultrasound guidance but in initial clinical cases, some areas of the liver have not been treated due to bone or gas obstructing the acoustic window for targeting.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Trauma Surgery, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany.
: Tactile gnosis derives from the interplay between the hand's tactile input and the memory systems of the brain. It is the prerequisite for complex hand functions. Impaired sensation leads to profound disability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!