A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mathematical model of cellular basis for the respiratory sinus arrhythmia. | LitMetric

The respiratory sinus arrhythmia (RSA) is a vagally mediated oscillation in cardiac cycle length at the frequency of breathing. We developed a mathematical model that predicted the temporal and frequency dependence of the RSA. We used the mathematical model to examine the underlying cellular basis for the RSA at the level of the sinus node. We alternated efferent vagal activity between a low and a high frequency at the frequency of breathing. This oscillation caused the rate of acetylcholine (ACh) release to oscillate between a low and a high rate at the frequency of breathing. ACh degradation followed linear pharmacokinetics for physiological concentrations of ACh. Therefore, the concentration of ACh in neuroeffector junctions of the sinus node oscillated at the frequency of breathing. Membrane potential responded rapidly to changes in the concentration of ACh relative to the rate of ACh degradation. Thus, the time course of the RSA depended on the rate of ACh degradation. Membrane potential oscillated at several integer multiples of frequency of breathing and at various higher frequencies, which were integer multiples of the frequency of breathing and the frequencies of firing of the sinus node. However, computing cardiac cycle length from membrane potential eliminated the higher frequencies. Therefore, cardiac cycle length oscillated at several integer multiples of the frequency of breathing, but not at these higher frequencies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-5193(05)80329-7DOI Listing

Publication Analysis

Top Keywords

frequency breathing
28
mathematical model
12
cardiac cycle
12
cycle length
12
sinus node
12
ach degradation
12
membrane potential
12
integer multiples
12
multiples frequency
12
higher frequencies
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!