Fast MR techniques and the application of water-soluble contrast agents allow the simultaneous examination of renal morphology and the functional aspects of glomerular filtration using bolus injections of Gd-DTPA. Spatial resolution is sufficient to resolve individual renal pyramids, but the quantitative examination of regions of interest (ROIs) is severely impeded by organ movements due to variations of the end-inspiratory position. A new image-processing scheme has been used and tested in 23 normal volunteers and patients. This scheme replaces a tedious frame-by-frame ROI analysis by positional correction of renal regions of all frames of the sequence such that the definition of the regions has to be performed only once. The signal intensities (SIs) of the local regions in each frame are used to compute statistics and to generate curves representing local temporal SI changes due to contrast agent excretion. The success rate of the procedure depends largely on the image quality and on the adherence to a proved acquisition protocol. The present article shows that the combination of MR and robust and reliable image-processing methods can be important for the highly automated analysis of a large number of images acquired as dynamic studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00004728-199109000-00002 | DOI Listing |
Bioengineering (Basel)
January 2025
Promaxo Inc., Oakland, CA 94607, USA.
This study evaluates the feasibility of using Haralick texture analysis on low-field, T2-weighted MRI images for detecting prostate cancer, extending current research from high-field MRI to the more accessible and cost-effective low-field MRI. A total of twenty-one patients with biopsy-proven prostate cancer (Gleason score 4+3 or higher) were included. Before transperineal biopsy guided by low-field (58-74mT) MRI, a radiologist annotated suspicious regions of interest (ROIs) on high-field (3T) MRI.
View Article and Find Full Text PDFBMC Cancer
January 2025
Department of Urology, Fujian Union Hospital, Fujian Medical University, Fuzhou, 350001, Fujian Province, China.
Background: Prostate cancer (PCa) is definitively diagnosed by systematic prostate biopsy (SBx) with 13 cores. This method, however, can increase the risk of urinary retention, infection and bleeding due to the excessive number of biopsy cores.
Methods: We retrospectively analyzed 622 patients who underwent SBx with prostate multiparametric MRI (mpMRI) from two centers between January 2014 to June 2022.
J Periodontal Res
January 2025
Division of Periodontology, Department of Oral Medicine, Infection, and Immunity, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
Aim: To assess tissue perfusion changes and wound healing biomarker levels after root coverage procedures with coronally advanced flap in combination with the cross-linked xenogeneic collagen matrix (CCMX), loaded either with a placebo or recombinant human platelet-derived growth factor-BB (rhPDGF).
Methods: This study was designed as a secondary analysis from a previously published clinical trial, and it assessed the tissue perfusion changes over 6 months around multiple gingival recession defects, treated with either with CCMX alone (control) or with CCMX + rhPDGF (test). High frequency Doppler ultrasonography (HFUS) scans were obtained at sites of interest at baseline, 2 weeks, 3 months, and 6 months after surgery.
Front Neurol
January 2025
School of Public Health, Shanxi Medical University, Taiyuan, China.
Background: Cognitive impairment (CI) is a condition in which an individual experiences noticeable impairment in thinking abilities. Long-term exposure to aluminum (Al) can cause CI. This study aimed to determine the relationship between CI and MRI-related changes in postroom workers exposed to Al.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China.
Background: Magnetic resonance (MR) diffusion-derived 'vessel density' (DDVD) is calculated according to: DDVD = Sb0/ROI - S/ROI, where S and S refer to the tissue signal when -value is 0 or 2 s/mm. S and ROI can also be approximated by other low -values diffusion-weighted imaging (DWI). This study investigates the influence of the second motion probing gradient -value and T2 on DDVD calculations of the liver, spleen, and liver simple cyst.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!