Since stereotactic body radiotherapy (SBRT) was started for patients with lung tumor in 1998 in our institution, x-ray fluoroscopic examination and slow computed tomography (CT) scan with a rotation time of 4 s have been routinely applied to determine target volumes. When lung tumor motion observed with x-ray fluoroscopy is larger than 8 mm, diaphragm control (DC) is used to reduce tumor motion during respiration. After the installation of a four-dimensional (4D) CT scanner in 2006, 4D CT images have been supplementarily acquired to determine target volumes. It was found that target volumes based on slow CT images were substantially different from those on 4D CT images, even for patients with lung tumor motion no larger than 8 mm. Although slow CT scan might be expected to fare well for lung tumors with motion range of 8 mm or less, the potential limitations of slow CT scan are unknown. The purpose of this study was to evaluate the geometrical differences in target volumes between slow CT and 4D CT imaging for lung tumors with motion range no larger than 8 mm in the upper and middle lobe. Of the patients who underwent SBR between October 2006 and April 2008, 32 patients who had lung tumor with motion range no larger than 8 mm and did not need to use DC were enrolled in this study. Slow CT and 4D CT images were acquired under free breathing for each patient. Target volumes were manually delineated on slow CT images (TV(slow CT)). Gross tumor volumes were also delineated on each of the 4D CT volumes and their union (TV(4D CT)) was constructed. Volumetric and statistical analyses were performed for each patient. The mean +/- standard deviation (S.D.) of TV(slow CT)/TV(4D CT) was 0.75 +/- 0.17 (range, 0.38-1.10). The difference between sizes of TV(slow CT) and TV(4D CT) was not statistically significant (P = 0.096). A mean of 8% volume of TV(slow CT) was not encompassed in TV(4D CT) (mean +/- S.D. = 0.92 +/- 0.07). The patients were separated into two groups to test whether the quality of target delineation on slow CT scans depends on respiratory periods below or above the CT rotation time of 4 s. No significant difference was observed between these groups (P = 0.229). Even lung tumors with motion range no larger than 8 mm might not be accurately depicted on slow CT images. When only a single slow CT scan was used for lung tumors with motion range of 8 mm or less, 95% confidence values for additional margins for TV(slow CT) to encompass TV(4D CT) were 4.0, 5.4, 4.9, 5.1, 1.8, and 1.7 mm for lateral, medial, ventral, dorsal, cranial, and caudal directions, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2968096DOI Listing

Publication Analysis

Top Keywords

target volumes
24
lung tumors
20
motion range
20
lung tumor
16
tumor motion
16
slow images
16
tumors motion
16
patients lung
12
slow scan
12
range larger
12

Similar Publications

Objective: Focused ultrasound (FUS)-mediated blood-brain barrier (BBB) opening is safe and potentially beneficial in patients with Alzheimer's disease (AD) for the removal of amyloid-beta (Aβ) plaques. However, the optimal BBB opening intervals and number of treatment sessions for clinical improvement remain undefined. Therefore, the aim of this study was to evaluate the safety and benefits of repeated and more extensive BBB opening alone.

View Article and Find Full Text PDF

Therapeutic Potential of Carbon Dots Derived from Phytochemicals as Nanozymes Exhibiting Superoxide Dismutase Activity for Anemia.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Beijing 100191, China.

Anemia is a potentially life-threatening blood disorder caused by an insufficient erythroblast volume in the circulatory system. Self-renewal failure of erythroblast progenitors is one of the key pathological factors leading to erythroblast deficiency. However, there are currently no effective drugs that selectively target this process.

View Article and Find Full Text PDF

Ecofriendly and biocompatible biochars derived from waste-branches for direct and efficient solid-phase extraction of benzodiazepines in crude urine sample prior to LC-MS/MS.

Mikrochim Acta

January 2025

School of Public Health, Hebei Key Laboratory of Occupational Health and Safety for Coal Industry, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.

Biochars (BCs) derived from waste-branches of apple tree, grape tree, and oak were developed for direct solid-phase extraction (SPE) of five benzodiazepines (BZDs) in crude urine samples prior to liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination. Scanning electron microscopy, elemental analyzer, X-ray diffractometry, N adsorption/desorption experiments, and Fourier transform infrared spectrometry characterizations revealed the existence of their mesoporous structure and numerous oxygen-containing functional groups. The obtained BCs not only possessed high affinity towards BZDs via π-π and hydrogen bond interactions, but also afforded the great biocompatibility of excluding interfering components from undiluted urine samples when using SPE adsorbents.

View Article and Find Full Text PDF

Objective: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).

Materials And Methods: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained.

View Article and Find Full Text PDF

Optimizing Care for Primary Glomerulonephritis: The Role of Thyroid Evaluation.

Endocr Metab Immune Disord Drug Targets

January 2025

Department of Endocrinology, Metabolism, and Diabetes, Istanbul University-Cerrahpasa, Istanbul, Turkey.

Background: The coexistence of primary glomerulonephritis and autoimmune thyroid disease has not been investigated.

Objective: This study aimed to assess thyroid morphology using sonography, determine the prevalence of autoimmune thyroid disorders, and evaluate thyroid function status in patients diagnosed with primary glomerulonephritis.

Materials And Methods: This single-center cross-sectional and observational study included 58 consecutive patients with primary glomerulonephritis and 58 healthy controls (HC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!