A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated colorimetric gadolinium assay for verification of clearance and estimation of glomerular filtration rate. | LitMetric

Automated colorimetric gadolinium assay for verification of clearance and estimation of glomerular filtration rate.

Clin Chim Acta

IDEXX Laboratories, Inc., One IDEXX Drive, Westbrook, ME 04092, USA.

Published: January 2009

Background: NSF (nephrogenic systemic fibrosis) is a potentially serious adverse effect for renal patients undergoing MRI (magnetic resonance imaging) procedures using gadolinium-containing contrast agents. There is therefore a need to verify clearance of these agents and to confirm appropriate renal status of patients treated with these drugs.

Methods: Serum samples from canine and feline subjects dosed with 0.1 mmol/kg of gadolinium agent, or from spiked samples were assayed for gadopentetate (Magnevist), gadodiamide (Omniscan) or gadoversetamide (OptiMARK) using a new dye reagent on the Olympus AU400. Accuracy was verified by ICP-MS.

Results: The reportable dynamic range is 3-600 micromol/l Gd. Split serum samples from animals dosed with 0.1 mmol/kg of gadopentetate ranged from 7-458 micromol/l Gd: y=1.121x+0.267, r=0.996, for the Olympus method as a function of Gd measurement by ICP-MS. Between-day imprecision was 1.3% CV-3.6% CV for samples ranging from 12-400 micromol/l Gd.

Conclusions: The assay is useful to verify the clearance of gadolinium and for evaluation of renal status by estimation of GFR using gadopentetate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2008.09.009DOI Listing

Publication Analysis

Top Keywords

verify clearance
8
renal status
8
serum samples
8
dosed mmol/kg
8
automated colorimetric
4
colorimetric gadolinium
4
gadolinium assay
4
assay verification
4
verification clearance
4
clearance estimation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!