A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Correlates of patient acceptance of the cardioverter defibrillator: cross-validation of the Florida Patient Acceptance Survey in Danish patients. | LitMetric

Background: Device acceptance may comprise one of the keys to identifying implantable cardioverter defibrillator (ICD) patients at risk for adverse health outcomes in clinical practice. We examined (1) the validity and reliability of the Florida Patient Acceptance Survey (FPAS) and (2) correlates of device acceptance in a large sample of Danish patients.

Methods: A cohort of consecutive patients (N = 566; 82.2% males; mean age = 61.9 +/- 14.3) implanted with an ICD since 1989 and still alive on November 1, 2006, completed a set of psychological questionnaires.

Results: The four-factor structure and the validity of the FPAS were confirmed, with the four factors accounting for 64.3% of the variance. The reliability, measured by Cronbach's alpha, was acceptable for the total scale and all subscales, ranging from 0.73 to 0.85. Correlates of poor device acceptance included older age (OR: 1.03; 95% CI: 1.01-1.05), symptomatic heart failure (OR: 3.59; 95% CI: 2.12-6.08), Type D personality (OR: 3.51; 95% CI: 1.95-6.30), anxiety (OR: 2.33; 95% CI: 1.24-4.38), depressive symptoms (OR: 2.24; 95% CI: 1.00-5.00), and ICD concerns (OR: 4.16; 95% CI: 2.55-6.80); having a partner was associated with better acceptance (OR: 0.53; 95% CI: 0.31-0.91), adjusting for demographic and clinical factors including shocks. Shocks were not associated with outcome (P = 0.59).

Conclusions: The FPAS was shown to be a valid and reliable measure of device acceptance in a large sample of Danish ICD patients. Psychological factors rather than clinical factors were the primary correlates of poor device acceptance, whereas having a partner was associated with better acceptance. These preliminary findings suggest that screening for psychological factors may aid clinicians in identifying patients at risk of poor device acceptance.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.2008.01158.xDOI Listing

Publication Analysis

Top Keywords

device acceptance
24
patient acceptance
12
poor device
12
acceptance
11
cardioverter defibrillator
8
florida patient
8
acceptance survey
8
icd patients
8
patients risk
8
acceptance large
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!