This study determined the compositional changes and microhardness of the cavity floor prepared by Er,Cr:YSGG and Er:YAG lasers and compared the results with the conventional method of bur preparation. Fifteen non-carious human molars were used in this study. On the buccal and lingual surfaces of each tooth, two cavities (mesio-distal 3 mm, inciso-gingival 3 mm, depth 2 mm) were prepared with two different laser devices (Er,Cr:YSGG laser; Waterlase MD and Er:YAG laser; KaVo Key Laser 3) and a high-speed turbine. The teeth were embedded into polyester resin and cross-sectioned. The microhardness measurements from the floor of each half cavity were recorded with the Vickers surface hardness tester. The remaining halves of the cavities were subjected to SEM-EDS atomic analysis. The results were statistically evaluated by one-way ANOVA and Kruskal Wallis tests (p = 0.05). No significant differences were observed among the microhardness values, quantities of Ca (Ca weight %), P (P weight %) and Ca/P ratio of the lased and conventionally prepared cavities (p > 0.05). The cavity preparation techniques and differences in laser devices did not significantly alter the composition and microhardness of dentin tissue. Both laser devices used in this study were observed to lead to minimal thermal damage in the dentin tissue and minimal thermally-induced changes in dentinal compositions.

Download full-text PDF

Source
http://dx.doi.org/10.2341/07-127DOI Listing

Publication Analysis

Top Keywords

laser devices
16
composition microhardness
8
microhardness dentin
8
dentin tissue
8
laser
7
microhardness
5
devices composition
4
dentin study
4
study determined
4
determined compositional
4

Similar Publications

To investigate the efficacy and mechanisms of fractional CO2 laser treatment for Vaginal Relaxation Syndrome (VRS) combined with recurrent bacterial vaginitis. Patients with VRS and recurrent bacterial vaginitis were randomly assigned to an intervention group (n = 60) receiving fractional CO2 laser therapy in addition to metronidazole, or a control group (n = 60) receiving metronidazole alone. Post-treatment assessments included vaginal relaxation, vaginal health index (VHI) scores, lactobacilli distribution, vaginal pH, recurrence rates, and the correlation between lactobacilli distribution and VHI.

View Article and Find Full Text PDF

A localized surface plasmon resonance (LSPR) sensor based on tapered optical fiber (TOF) using hollow gold nanoparticles (HAuNPs) for measuring the refractive index (RI) is presented. This optical fiber sensor is a good candidate for a label-free RI biosensor. In practical biosensors, bioreceptors are immobilized on nanoparticles (NPs) that only absorb specific biomolecules.

View Article and Find Full Text PDF

Ultraelastic Lead Halide Perovskite Films via Direct Laser Patterning.

ACS Nano

January 2025

College of Materials and Chemistry & Chemical Engineering, Nuclear Technology Key Laboratory of Earth Science, Chengdu University of Technology, Chengdu 610059, China.

The precise patterning of elastic semiconductors holds encouraging prospects for unlocking functionalities and broadening the scope of optoelectronic applications. Here, perovskite films with notable elasticity capable of stretching over 250% are successfully fabricated by using a continuous-wave (CW) laser-patterning technique. Under CW laser irradiation, perovskite nanoparticles (NPs) undergo meticulous crystallization within the thermoplastic polyurethane (TPU) matrix, which yields the capability of an unparalleled stretch behavior.

View Article and Find Full Text PDF

Development of a portable multi-step microfluidic device for point-of-care nucleic acid diagnostics.

Anal Chim Acta

January 2025

State Key Laboratory of Microbial Technology, Microbial Technology Institute, Shandong University, Qingdao, Shandong, 266237, China. Electronic address:

Background: The COVID-19 pandemic has significantly affected global health, economies, and societies, and highlighted the urgent need for rapid, sensitive, affordable, and portable diagnostic devices for respiratory diseases, especially in areas with limited resources. In recent years, there has been rapid development in integrated equipments using microfluidic chips and biochemical detection technologies. However, these devices are expensive and complex to operate, showing limited feasibility for in point of care tests (PoCTs).

View Article and Find Full Text PDF

To compare the effects of home-based rehabilitation and occlusal splints or centre-based rehabilitation in patients with temporomandibular joint disorders (TMD). A systematic review and meta-analysis. PubMed, Embase, Cochrane Library, Web of Science and ClinicalTrials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!