Hypothesis: To study variations in human cochlea anatomy with potential implications for cochlear implantation surgery.
Background: A comprehension of the anatomic variations of the human cochlea is essential for understanding the degree of surgical trauma induced by inserting various electrode arrays in cochlear implantation surgery. Variations in anatomy may also limit the potential for performing hearing preservation.
Methods: We studied 73 archival, nonselected, adult, corrosion casts of human inner ears. Anatomic reference points were constructed from photographic reproductions taken at different angles, and various dimensions were assessed using planimetry. Anatomic variants with particular clinical/surgical interests were pinpointed.
Results: Results showed that the human cochlea is individually shaped, varying greatly in dimensions ("fingerprint"). The outer cochlear wall length ranged from 38.6 to 45.6 mm with a mean length of 42.0 mm. The first turn represented 53% of the total length and ranged from 20.3 to 24.3 mm. The number of quadrants varied from slightly more than 8 to 12. The facial nerve canal ran in close proximity to the upper first turn explaining facial nerve excitement during stimulation of electrodes in this region in some instances. The internal diameter (height) of the cochlear tube in the first turn varied broadly (1.6-2.6 mm), occasionally with limited space for conventional implants.
Conclusion: The human cochlea exhibits extensive anatomic variations. These variations will influence the location of cochlear implant arrays and affect the potential of hearing preservation surgery. Our results may explain the surgeon's difficulties sometimes to insert electrode arrays even in so-called "normal" cochleae.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAO.0b013e31818a08e8 | DOI Listing |
HardwareX
March 2025
Center for Frontier Medical Engineering, Chiba University, Chiba, Japan.
Thanks to affordable 3D printers, creating complex designs like anatomically accurate dummy heads is now accessible. This study introduces dummy heads with 3D-printed skulls and silicone skins to explore crosstalk cancellation in bone conduction (BC). Crosstalk occurs when BC sounds from a transducer on one side of the head reach the cochlea on the opposite side.
View Article and Find Full Text PDFGenome Med
January 2025
Otology & Neurotology Group CTS495, Instituto de Investigación Biosanitario, Ibs.GRANADA, Universidad de Granada, 18071, Granada, Spain.
Background: Familial Meniere's disease (FMD) is a rare polygenic disorder of the inner ear. Mutations in the connexin gene family, which encodes gap junction proteins, can also cause hearing loss, but their role in FMD is largely unknown.
Methods: We retrieved exome sequencing data from 94 individuals in 70 Meniere's disease (MD) families.
Cureus
December 2024
School of Dental Medicine, Lake Erie College of Osteopathic Medicine, Bradenton, USA.
Introduction: Dentists and dental professionals report a high prevalence of noise-induced hearing loss (NIHL) and related symptoms. Chronic exposure to high-frequency dental instrument sounds, which can damage the outer hair cells (OHCs) of the cochlea, is strongly linked to their NIHL. Similarly, dental students in teaching clinics often report symptoms associated with NIHL.
View Article and Find Full Text PDFOtol Neurotol
February 2025
Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota.
Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).
Study Design: Retrospective cohort study.
Setting: Tertiary academic medical center.
Objective: The aim of this study is to test the feasibility of a custom 3D-printed guide for performing a minimally invasive cochleostomy for cochlear implantation.
Study Design: Prospective performance study.
Setting: Secondary care.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!