A method for sampling and electrophoretic analysis of aqueous plugs segmented in a stream of immiscible oil is described. In the method, an aqueous buffer and oil stream flow parallel to each other to form a stable virtual wall in a microfabricated K-shaped fluidic element. As aqueous sample plugs in the oil stream make contact with the virtual wall, coalescence occurs and sample is electrokinetically transferred to the aqueous stream. Using this virtual wall, two methods of injection for channel electrophoresis were developed. In the first, discrete sample zones flow past the inlet of an electrophoresis channel and a portion is injected by electroosmotic flow, termed the "discrete injector". With this approach at least 800 plugs could be injected without interruption from a continuous segmented stream with 5.1% RSD in peak area. This method generated up to 1,050 theoretical plates, although analysis of the injector suggested that improvements may be possible. In a second method, aqueous plugs are sampled in a way that allows them to form a continuous stream that is directed to a microfluidic cross-style injector, termed the "desegmenting injector". This method does not analyze each individual plug but instead allows periodic sampling of a high-frequency stream of plugs. Using this system at least 1000 injections could be performed sequentially with 5.8% RSD in peak area and 53,500 theoretical plates. This method was demonstrated to be useful for monitoring concentration changes from a sampling device with 10 s temporal resolution. Aqueous plugs in segmented flows have been applied to many different chemical manipulations including synthesis, assays, sampling processing and sampling. Nearly all such studies have used optical methods to analyze plug contents. This method offers a new way to analyze such samples and should enable new applications of segmented flow systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2615240 | PMC |
http://dx.doi.org/10.1021/ac801317t | DOI Listing |
Macromol Rapid Commun
November 2024
Faculty of Engineering, China University of Geosciences, Wuhan, Hubei, 430074, China.
Intelligent-responsive temporary plugging agents (TPAs) have great potential in the field of oil and gas resource extraction due to their self-adaptability to the environment. However, the transport mechanism of oil and gas molecules, such as aqueous methane solution in intelligent-responsive TPA-modified nano-channels and the blocking behavior of TPA, have not been verified yet. In this work, dissipative particle dynamics simulations (DPD) are conducted to investigate the velocity distribution and the force characteristics of aqueous methane solutions under different driving velocities, as well as the blocking effect of TPA to the flow of solution.
View Article and Find Full Text PDFGels
July 2024
School of Petroleum Engineering, Xi'an Shiyou University, Xi'an 710065, China.
In order to solve the problem of gas channeling during CO flooding in low-permeability reservoirs, a novel CO responsive gel channeling system was prepared by using carrageenan, branched polyethylene imide and ethylenediamine under laboratory conditions. Based on the Box-Behnken response surface design method, the optimal synthesis concentration of the system was 0.5 wt% carrageenan, 2.
View Article and Find Full Text PDFPolymers (Basel)
June 2024
Cooperative Innovation Center of Unconventional Oil and Gas, Yangtze University, Wuhan 430100, China.
Gel plugging agents have become one of the preferred methods for plugging in complex and severe loss conditions during drilling due to their good adaptability to loss channels. To address the common issue of poor temperature resistance in gel-based plugging agents, high-temperature-resistant gel plugging materials were synthesized through the molecular design of polymers, modifying existing agents. Based on the temperature and salt resistance of the aqueous solution of an acrylamide (AM)/N-vinylpyrrolidone (NVP) binary copolymer, temperature-resistant monomer sodium styrene sulfonate (SSS) was introduced and reacted in a polyvinyl alcohol (PVA) aqueous solution.
View Article and Find Full Text PDFOcul Surf
October 2024
Cornea & Anterior Segment Service, L V Prasad Eye Institute, Bhubaneswar, Odisha, 751024, India. Electronic address:
Filamentary keratitis (FK) is a clinical sign of underlying ocular and systemic conditions. FK can cause significant irritation, tearing, and photophobia in the eye. It is a refractory debilitating condition caused by dry eye that affects the day-to-day activities of patients.
View Article and Find Full Text PDFCureus
May 2024
Department of Ophthalmology, Hospital Tengku Ampuan Rahimah, Klang, MYS.
We report a case of successful argon laser synechiolysis as a non-invasive alternative for peripheral anterior synechiae release after trabeculectomy in a young patient with steroid-induced ocular hypertension. Steroid-induced ocular hypertension is a known complication of vernal keratoconjunctivitis due to prolonged treatment with steroids. In refractive conditions, augmented trabeculectomy becomes the surgery of choice in these patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!