A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of ascorbic acid in human plasma with a view to stability using HPLC with UV detection. | LitMetric

Determination of ascorbic acid in human plasma with a view to stability using HPLC with UV detection.

J Sep Sci

Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Pardubice, Czech Republic.

Published: October 2008

A method for the measurement of ascorbic acid using HPLC with UV detection and investigation into the protein precipitation techniques with regard to stability and recovery are described. The effectiveness of various protein precipitants was tested. Stability of ascorbic acid samples for analysis was investigated over 10 h. Ascorbic acid samples extracted with metaphosphoric acid were stable on a cooled autosampler (4 degrees C) for at least 10 h (with a decline of 1.8% for ascorbic acid solution and 2.8% for plasma). Perchloric acid as protein precipitant for ascorbic acid was unsuitable (with a decline of 36.0% for ascorbic acid solution and 7.3% for plasma). Analytical performance of this method is satisfactory. The intra- and interassay coefficients of variation were 2.1% (n = 10) and 5.8% (n = 12), respectively. The calibration curve was linear with the tested range of 2.0-250.0 micromol/L. The recovery was 96.1% with CV = 4.8% (n = 6) and the LOD was 3 micromol/L. The preliminary reference ranges of ascorbic acid in a group of blood donors are 50.8 +/- 22.4 micromol/L. This assay is a highly sensitive and reproducible HPLC method for the determination of ascorbic acid in human plasma.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.200800303DOI Listing

Publication Analysis

Top Keywords

ascorbic acid
36
acid
11
determination ascorbic
8
acid human
8
human plasma
8
hplc detection
8
ascorbic
8
acid samples
8
acid solution
8
plasma
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!