Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: We report the late outcomes in 411 consecutive patients undergoing drug-eluting stent (DES) implantation by a single operator between 2003-2006.
Methods: Prospective registry with continuous follow up. Patients with stable angina (SA) or acute coronary syndrome (ACS) received DES for long lesions, small vessels, chronic total occlusion, bifurcation, aorto-ostial, left main, post atherectomy or saphenous vein graft lesions, multivessel/multilesion single-vessel (V) disease, in-stent restenosis (ISR) or diabetes.
Results: Age range: 34-86 years. One hundred sixty-six (40.3%) had ACS, 98.3% hypercholesterolemia and 14.6% diabetes. Two hundred sixty-one (63.5%) had percutaneous coronary intervention (PCI) to 1V and 150 (36.5%) to >1V. Six hundred seven V were treated. Two hundred fifty-nine patients (63%) had multilesion PCI, and 109 (26.5%) 1V multilesion PCI. Two hundred ninety-three (71.3%) patients had long lesions and 224 had Vs < 2.75 mm diameter. 75.5% of lesions were Type B2/C. 1-8 stents were implanted/patient. Eight hundred twenty-two of 883 stents were DES. One hundred eight patients received > or = 1 stent of < or = 2.5 mm diameter and 246 patients received stents greater than or equal to 20 mm long. Twenty-five patients developed late complications. ISR occurred in 23, 3.5-38 months after DES implantation. Three had sudden late DES thrombosis (LST). One-third also had ISR. Twenty of twenty-five required PCI, 1 CABG and 4 medical treatment. Subsequently, 3 of the 20 required further PCI for recurrent ISR and 1 CABG. 9 patients died during 1-5-year follow up.
Conclusions: In "real-world" patients at increased risk of ISR after bare-metal stenting (BMS), "off-label" DES implantation has a low incidence of late complications. The most common is ISR which presents later than after BMS. Acute LST is serious but unusual and may be accompanied by ISR.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!