Study Design: Single institution, single surgeon retrospective review.

Objective: To investigate if the use of titanium mesh cage on the site of infection could be beneficial for successful outcome of the operative treatment for pyogenic spondylitis.

Summary Of Background Data: There is a controversy concerning the optimal treatment for pyogenic spondylitis regarding approach, instrumentation and staging. This large series reports on single-stage instrumented open and minimally invasive surgery for septic spondylitis.

Methods: Twenty-four patients aged 57 +/- 16 years suffering from persistent or complicated septic spondylitis were treated by a total of 25 single stage combined surgeries (first: anterior debridement/partial vertebrectomy plus mesh cage filled with autologous bone graft; second: pedicle screw fixation with open and minimal invasive techniques). The indications for surgery included neurologic compromise, significant vertebral body destruction with kyphosis associated with segmental instability, failure of medical treatment, and/or epidural/ paravertebral abscess formation. Needle biopsy was performed in all patients before surgery. Patients were evaluated before and after surgery in terms of pain and neurologic level, sagittal segmental spinal balance, radiologic fusion and recovery.

Results: All but 1 tetraplegic patient with simultaneous cervical and lumbar spondylitis, who died because of massive clot lung embolism 2 months after surgery, were followed for 56 months (range, 31-116 months) The visual analogue scale score improved from 6.5 before surgery to 1.8 after surgery. The segmental kyphotic deformity was corrected at an average of 6 degrees, without cage settling. An insignificant loss of kyphosis correction of an average 0.6 degrees was measured in the thoracolumbar junction only. Blood loss, surgical time, and surgical complications were significant less in the patients who operated with minimal invasive technique. Patients with incomplete neurologic impairment improved after surgery. Physical function (SF-36) averaged 72 1 year after surgery. All operated patients had resolution of infection. There was neither migration of mesh cage nor posterior instrumentation failure at the last follow-up observation.

Conclusion: The present study showed that radical debridement of spinal infection and anterior insertion of titanium cage, filled with autogenous bone graft, secured with pedicle screw instrumentation should have had a beneficial influence on the eradication of infection, segmental and global spinal reconstruction and fusion. Supplementary posterior minimal invasive pedicle screw fixation eliminates posterior soft tissue injury and preserves blood supply, and reduces surgical time, blood loss, and surgical complications.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0b013e318187875eDOI Listing

Publication Analysis

Top Keywords

mesh cage
16
pedicle screw
12
minimal invasive
12
surgery
9
beneficial influence
8
titanium mesh
8
spinal reconstruction
8
septic spondylitis
8
treatment pyogenic
8
cage filled
8

Similar Publications

Preparation of Silicon Nanopillar Arrays Using Reactive Ion Etching with a Faraday Cage.

ACS Appl Mater Interfaces

January 2025

Advanced Research Institute of Multidisciplinary Sciences, Beijing Institute of Technology, Beijing 100081, China.

Faraday cages are extensively utilized in plasma-based etching and deposition processes to regulate ion behavior due to their shielding effect on electromagnetic fields. Herein, vertical silicon nanopillar arrays are fabricated through SF and O reactive ion etching. By incorporation of a Faraday cage in the plasma equipment, the impact of the Faraday cage on the morphology of the silicon nanopillars is analyzed; the Faraday cage blocks out the sputtered particles and eradicates the formation of silicon nanograss.

View Article and Find Full Text PDF
Article Synopsis
  • Cage subsidence can negatively affect lumbar fusion procedures, with material selection (PEEK vs. 3D-Ti) influencing this issue; the study aims to compare their subsidence rates.
  • The systematic search reviewed 265 patients from three high-quality studies, focusing on cage subsidence and classified subsidence rates using a specific method.
  • Results indicated that 3D-Ti cages have a significantly lower rate of subsidence compared to PEEK cages, with less severe subsidence and better overall performance.
View Article and Find Full Text PDF

Background: Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.

Objective: This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).

View Article and Find Full Text PDF

Introduction: Renal cell carcinoma (RCC) accounts for 2-3% of adult malignant tumors, often metastasizing to bones, especially the spine. Spinal metastasis has a poor prognosis, but solitary spinal tumors have better outcomes with targeted chemotherapy, radiotherapy, and newer surgical approaches. Due to RCC's high vascularity and resistance to treatments, en bloc vertebrectomy with anterior and posterior fixation is the gold standard for solitary lesions.

View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!