Ultrasound evaluation of the abductor hallucis muscle: Reliability study.

J Foot Ankle Res

AUT University, School of Rehabilitation & Occupation Studies, Health & Rehabilitation Research Centre, Private Bag 92006, Auckland, 1142, New Zealand.

Published: September 2008

Background: The Abductor hallucis muscle (AbdH) plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults.

Methods: The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability.

Results: The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99-0.99); medio-lateral width an ICC: of 0.97 (95% CI: 0.92-0.97) and cross-sectional area an ICC of 0.98 (95% CI: 0.98-0.99). Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98); medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96) and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88).

Conclusion: Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2565658PMC
http://dx.doi.org/10.1186/1757-1146-1-12DOI Listing

Publication Analysis

Top Keywords

dorso-plantar thickness
12
medio-lateral width
12
cross-sectional area
12
icc 097
12
097 95%
12
abductor hallucis
8
hallucis muscle
8
diagnostic ultrasound
8
asymptomatic subjects
8
reliability demonstrated
8

Similar Publications

Current evidence regarding 2D ultrasonography monitoring of intrinsic foot muscle properties: A systematic review.

Heliyon

August 2023

Department of Rehabilitation Sciences, Musculoskeletal Rehabilitation Research Group, KU Leuven, Spoorwegstraat 12, 8200 Brugge, Belgium.

Background: Ultrasonography can discriminate between intrinsic and extrinsic foot muscle properties and has therefore gained considerable popularity as an indirect strength evaluation. However, an overview on the use of ultrasound for assessing intrinsic foot musculature (IFM) is currently lacking.

Research Question: What is the current evidence regarding (1) 2D ultrasonography protocols and its reliability? (2) Reference values for cross-sectional area and dorso-plantar thickness evaluation in asymptomatic and symptomatic persons?

Methods: The PRISMA guidelines were used to conduct this systematic review.

View Article and Find Full Text PDF

The effect of age on muscle characteristics of the abductor hallucis in people with hallux valgus: a cross-sectional observational study.

J Foot Ankle Res

June 2015

Department of Podiatry, Health & Rehabilitation Research Institute, Auckland University of Technology, Private Bag 92006, Auckland, 1142 New Zealand.

Background: The abductor hallucis muscle plays an important role in maintaining alignment of the first metatarsophalangeal joint. The aims of this study were (1) to determine differences in abductor hallucis muscle characteristics in people with hallux valgus between three age groups (20-44 years, 45-64 years, and 65+ years); and (2) to determine the association between age and abductor hallucis size and quality.

Methods: Characteristics of the abductor hallucis muscle were measured in 96 feet with hallux valgus using musculoskeletal ultrasound.

View Article and Find Full Text PDF

Ultrasonic evaluation of the abductor hallucis muscle in hallux valgus: a cross-sectional observational study.

BMC Musculoskelet Disord

January 2013

School of Podiatry, Health & Rehabilitation Research Institute, AUT University, Auckland, New Zealand.

Background: The aim of the study was to investigate the abductor hallucis muscle characteristics, defined as dorso-plantar (DP) thickness, medio-lateral (ML) width, and cross-sectional area (CSA) in relation to the severity of hallux valgus using musculoskeletal ultrasound. One hundred and two feet, mean (SD) age of 60.3 (20.

View Article and Find Full Text PDF

Hypertrophy of abductor hallucis muscle is one of the reported causes of compression of tibial nerve branches in foot, resulting in tarsal tunnel syndrome. In this study, we dissected the foot (including the sole) of 120 lower limbs in 60 human cadavers (45 males and 15 females), aged between 45 and 70 years to analyze the possible impact of abductor hallucis muscle in compression neuropathy of tibial nerve branches. We identified five areas in foot, where tibial nerve branches could be compressed by abductor hallucis.

View Article and Find Full Text PDF

Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines.

J Foot Ankle Res

November 2009

School of Rehabilitation & Occupation Studies, Health & Rehabilitation Research Centre, AUT University, Private Bag 92006, Auckland, 1142, New Zealand.

Background: Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System.

Methods: The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!