A direct liquid chromatographic enantioselective separation of venlafaxine and 11 analogs was obtained in the normal phase mode using Chiralpak AD. For some compounds, a comparison between the enantioseparation using coated and immobilized amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phases (Chiralpak AD and Chiralpak IA, respectively) was made. The best separations were achieved on Chiralpak AD with ethanol as alcoholic modifier in a mobile phase made basic by DEA addition: separation factor ranges between 2.08 and 1.15 and resolution factor between 7.0 and 1.0. Using the same CSP and 2-propanol doped with TFA as acidic modifier, 10 compounds were enantioseparated with separation factor ranging between 1.40 and 1.04 and resolution factor between 3.1 and 0.3. The use of ethanol as alcoholic modifier also has the advantage of better solubility of the compounds in the mobile phase. The nature of the substituent (electron donating or withdrawing) affects in general the separation factor. A memory effect that involves a long equilibration time of the CSP is present when switching from an acidic mobile phase to a basic one.

Download full-text PDF

Source
http://dx.doi.org/10.1002/chir.20633DOI Listing

Publication Analysis

Top Keywords

mobile phase
12
separation factor
12
liquid chromatographic
8
venlafaxine analogs
8
chiral stationary
8
stationary phases
8
ethanol alcoholic
8
alcoholic modifier
8
phase basic
8
resolution factor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?