Moxifloxacin (MXF) is an 8-methoxyquinolone with high activity against Gram-positive bacteria. In an experimental model of aortic valve endocarditis (EAVE), the efficacy of MXF was evaluated against a strain of methicillin-resistant Staphylococcus aureus (MRSA). Rabbits with catheter-induced aortic valve vegetations were randomly assigned to a control group or to groups receiving MXF 20 mg/kg intravenous (i.v.) twice a day (bid) or vancomycin (VAN) 30 mg/kg i.v. bid for a total of eight doses (4 days). Rabbits were sacrificed 15 h after the last dose of antibiotics. In another group, treatment with MXF was extended to 5 days and rabbits were sacrificed 5 days after the last dose (10th dose) of MXF in order to detect possible relapses of endocarditis after the end of treatment (test-of-cure (TOC) study). Both MXF and VAN significantly reduced the bacterial load in vegetations (P < 0.001 vs. controls). All animals in the MXF-TOC group had sterile vegetations. MXF given at a dose of 20 mg/kg i.v. bid for 4 days was equally effective as VAN in the treatment of EAVE due to MRSA. When treatment with MXF was extended to 5 days, the cure rate reached 100% and no relapses of endocarditis were observed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijantimicag.2008.07.021 | DOI Listing |
J Cardiothorac Surg
January 2025
Cardiac Surgery Center, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Affiliated Hospital of University of Electronic Science and Technology, Chengdu, Sichuan Province, 610072, China.
Objective: To explore the safety and efficacy of low-intensity anticoagulation in patients after On-X mechanical aortic valve replacement.
Methods: A total of 104 patients undergoing aortic valve replacement in Cardiac Surgery Department of Sichuan Provincial People's Hospital from December 2018 to December 2021 were randomly divided into low-intensity anticoagulant (INR:1.5-2.
Background: Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce.
View Article and Find Full Text PDFJ Am Soc Echocardiogr
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Phoenix, Arizona, USA.
Background: Aortic stenosis (AS) is a complex condition with various hemodynamic subtypes, each with distinct clinical profiles and outcomes. This study aimed to assess the characteristics and outcomes of different AS phenotypes based on flow and gradient patterns.
Methods: In this retrospective cohort study, we included 930 patients who underwent transcatheter aortic valve replacement (TAVR) for severe symptomatic AS at Mayo Clinic sites from 2012-2017.
Pediatr Transplant
February 2025
The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
Background: Partial heart transplantation (PHT) is a novel procedure for children in need of a growing valve replacement option. One challenge is identifying suitable donor valves. Semilunar heart valves from patients receiving a retransplant may be a source, however their functionality and growth potential especially at the time of retransplant are unknown.
View Article and Find Full Text PDFThorac Cardiovasc Surg
January 2025
Cardiothoracic surgery, CHU de Rennes, Rennes, France.
Background: The long-term comparative results between porcine and pericardial bioprostheses for surgical aortic valve replacement (SAVR) is debated. Scarce information exists concerning direct comparative evaluation among contemporary devices. We compared late and very late results in a single center series (N=3,983 cases).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!