Tracheal compliance and limit flow rate changes in a murine model of asthma.

Sci China C Life Sci

Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA 01609, USA.

Published: October 2008

Trachea is the unique passage for air to flow in and out. Its tone is of importance for the respiration system. However, investigation on how tracheal tone changes due to asthma is limited. Aiming at studying how the mechanical property changes due to asthma as well as the compliance and flow limitation, the following methods are adopted. Static and passive pressure-volume tests of rats' trachea of the asthmatic and control groups are carried out and a new type of tube law is formulated to fit the experimental data, based on which changes of compliance and limit flow rate are investigated. In order to give explanation to such changes, histological examinations with tracheal soft tissues are made. The results show that compliance, limit flow rate and material constants included in the tube law largely depend on the longitudinal stretching ratio. Compared with the control group, the tracheal compliance of asthmatic animals decreases significantly, which results in an increased limit flow rate. Histological studies indicate that asthma can lead to hyperplasia/hypertrophy of smooth muscle cells, and increase elastin and collagen fibres in the muscular membrane. Though decreasing compliance increases stability, during the onset of asthma, limit flow rate is much smaller due to the lower transmural pressure. Asthma leads to a stiffer trachea and the obtained results reveal some aspects relevant to asthma-induced tracheal remodelling.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11427-008-0108-7DOI Listing

Publication Analysis

Top Keywords

limit flow
20
flow rate
20
compliance limit
12
tracheal compliance
8
changes asthma
8
tube law
8
flow
7
asthma
6
tracheal
5
limit
5

Similar Publications

A highly sensitive and rapid LC-MS/MS method was developed and validated for the quantification of dexamethasone in rat plasma and brain tissue. Protein precipitation method was used for sample preparation. The separation of dexamethasone and the IS (labetalol) was achieved on an Atlantis dC column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 25/75, v/v) delivered at 0.

View Article and Find Full Text PDF

Microplastics (MPs) are ubiquitous and are increasing globally, but there is limited information available on their presence in freshwater ecosystems. This research work aims to investigate the abundance, sinking behavior, and risk assessment of MPs in the freshwater River Basantar, Jammu & Kashmir, India. Microplastic abundance in sediments was recorded in the range of 1-6 items g, with a mean abundance of 3 ± 1.

View Article and Find Full Text PDF

Development of a dual-mode lateral flow assay based on structure-guided aptamers for the detection of capsaicin in gutter oils.

Biosens Bioelectron

December 2024

Teaching and Research Office of Food Safety, School of Public Course, Bengbu Medical College, Bengbu, 233000, China. Electronic address:

The construction of structure-guided aptamers and the ultra-sensitive aptamer-based lateral flow assays (Apt-LFA) integrated detection method hold significant potential for food analysis. Using an engineered modified sequence strategy, we successfully developed the aptamer Cap-1-2M4, significantly enhancing its affinity for capsaicin (CAP) to 0.6197 ± 0.

View Article and Find Full Text PDF

Establishing age-group specific reference intervals of human salivary proteome and its preliminary application for epilepsy diagnosis.

Sci China Life Sci

December 2024

State Key Laboratory of Medical Proteomics, Beijing Proteome Research Center, National Center for Protein Sciences (Beijing), Beijing Institute of Lifeomics, Beijing, 102206, China.

Salivary proteins serve multifaceted roles in maintaining oral health and hold significant potential for diagnosing and monitoring diseases due to the non-invasive nature of saliva sampling. However, the clinical utility of current saliva biomarker studies is limited by the lack of reference intervals (RIs) to correctly interpret the testing result. Here, we developed a rapid and robust saliva proteome profiling workflow, obtaining coverage of >1,200 proteins from a 50-µL unstimulated salivary flow with 30 min gradients.

View Article and Find Full Text PDF

Rapid thrombolysis is very important to reduce complications caused by vascular blockage. A promising approach for improving thrombolysis efficiency is utilizing the permanent magnetically actuated locomotion of nanorobots. However, the thrombolytic drug transportation efficiency is challenged by in-plane rotating locomotion and the insufficient drug penetration limits further improvement of thrombolysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!