The present study was designed to take advantage of telemetry data acquisition and develop an easy and reliable system to servocontrol renal perfusion pressure (RPP). Digitized pressure signals from lower abdominal aorta in rats, reflecting RPP, was obtained by a telemetry device and dynamically exported into an Excel worksheet. A computer program (LabVIEW) compared the RPP data with a preselected pressure range and drove a bidirectional syringe pump to control the inflation of a vascular occluder around the aorta above renal arteries. When RPP was higher than the preselected range, the syringe pump inflated the occluder and decreased RPP, and vice versa. If RPP was within range, there was no action. In this way, RPP was servocontrolled within the desired range. In experiments with norepinephrine- or ANG II-induced acute increases in systemic arterial pressure (120-145 mmHg), the system controlled RPP at a constant range of 100-105 mmHg within 30-50 s and differentiated the pressure-dependent and -independent effects on renal functions. In Dahl S rats with high-salt-induced hypertension, this system maintained RPP at 100-120 mmHg over 10 days, while systemic arterial pressures were 150 +/- 5.9 mmHg in uncontrolled animals. This system also has the ability of simultaneity and multiplexing to control multiple animals. Our results suggest that this is an effective and reliable system to servocontrol RPP, which can be easily established with general computer knowledge. This system provides a powerful tool and may greatly facilitate the studies in pressure-dependent/-independent effects of a variety of cardiovascular factors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2584867PMC
http://dx.doi.org/10.1152/ajpregu.90631.2008DOI Listing

Publication Analysis

Top Keywords

rpp
10
servocontrol renal
8
renal perfusion
8
perfusion pressure
8
reliable system
8
system servocontrol
8
syringe pump
8
systemic arterial
8
system
6
pressure
5

Similar Publications

This study presents the design, modeling, and validation of a mixing screw for energy-efficient single-screw extrusion. The screw features a short length-to-diameter (L/D) ratio of 8:1 and incorporates double flights with variable pitch and counter-rotating mixing slots. These features promote enhanced plastication by breaking up the solid bed and improving thermal homogeneity through backflow mechanisms relieving a 3.

View Article and Find Full Text PDF

An intelligent transportation system (ITS) offers commercial and personal movement through the smart city (SC) communication paradigms with hassle-free information sharing. ITS designs and architectures have improved via information and communication technologies in recent years. The information shared through the communication medium in SCs is exposed to adversary risk, resulting in privacy issues.

View Article and Find Full Text PDF

Introduction: Research-practice-policy partnerships are shifting the academic research paradigm toward collaboration and research-informed action at community and policy levels. In this case study, researchers partnered with philanthropic foundations to actualize data findings from a rigorous, longitudinal study.

Context: In 2016, a survey of post-9/11 military veterans began assessing veterans' well-being in key domains: health, vocation (education and employment), finances, and social relationships.

View Article and Find Full Text PDF

Background And Aims: An exaggerated hemodynamic response to endotracheal intubation is observed in hypertensive patients, and its attenuation proves challenging. The role of oral ivabradine, a unique heart rate-lowering drug with a favorable hemodynamic profile, is not yet studied. The aim of this study was to evaluate the effect of oral ivabradine on the attenuation of hemodynamic response to endotracheal intubation in hypertensive surgical patients assessed by rate pressure product (RPP), which is a very reliable indicator of myocardial oxygen demand.

View Article and Find Full Text PDF

Evolution of Two-Dimensional Perovskite Films Under Atmospheric Exposure and Its Impact on Photovoltaic Performance.

ACS Appl Mater Interfaces

January 2025

Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, China.

Two-dimensional (2D) Ruddlesden-Popper perovskites (RPPs) have garnered significant attention due to their enhanced stability compared with their three-dimensional counterparts. However, the power conversion efficiency (PCE) of 2D perovskite solar cells (2D-PSCs) remains lower than that of 3D-PSCs. Understanding the microstructural evolution of 2D perovskite films during fabrication is essential for improving their performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!