Introduction: The potential benefits of remote robotic navigation for catheter ablation procedures have not been demonstrated in controlled clinical trials. The purpose of this study was to compare remote magnetic catheter navigation to manual navigation for the ablation of common supraventricular arrhythmias.
Methods And Results: Patients with supraventricular arrhythmias due to atrioventricular (AV) nodal reentry, accessory pathways, or undergoing AV junctional ablation for complete heart block were randomized in a 3:1 ratio between magnetic (Niobe system and Helios II catheter, Stereotaxis, Inc., St. Louis, MO) and manual navigation for radiofrequency ablation at 13 centers. The primary endpoint of the study was total fluoroscopic time. Fifty-six patients were randomized to magnetic navigation and 15 to manual navigation. AV nodal reentry was the most common arrhythmia in both groups. Total fluoroscopy time was reduced in the magnetic navigation group (median 17.8 minutes, interquartile (IQ) range 9.9,27.8 minutes) compared to manual navigation (27.1, IQ 19.0,48.0, P < 0.05). The acute success rates (91% for magnetic and 87% for manual navigation, P > 0.05) did not differ between groups. The number of lesions delivered was less for magnetic navigation (6, IQ 4,9 vs 10, IQ 7, 26, P < 0.05). Total procedure time (median 151, IQ 111, 221 minutes magnetic and 151, IQ 110, 221 minutes manual) and complication rates (5.4% patients magnetic and 6.7% patients manual) were similar between the groups (both P > 0.05).
Conclusions: Remote magnetic catheter navigation reduces fluoroscopic time and radiofrequency lesion deliveries for the ablation of common supraventricular arrhythmias compared to manual catheter navigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.2008.01183.x | DOI Listing |
J Pers Med
January 2025
Department of Ophthalmology, Mayo Clinic, Rochester, MN 55905, USA.
: Augmented reality (AR) may allow vitreoretinal surgeons to leverage microscope-integrated digital imaging systems to analyze and highlight key retinal anatomic features in real time, possibly improving safety and precision during surgery. By employing convolutional neural networks (CNNs) for retina vessel segmentation, a retinal coordinate system can be created that allows pre-operative images of capillary non-perfusion or retinal breaks to be digitally aligned and overlayed upon the surgical field in real time. Such technology may be useful in assuring thorough laser treatment of capillary non-perfusion or in using pre-operative optical coherence tomography (OCT) to guide macular surgery when microscope-integrated OCT (MIOCT) is not available.
View Article and Find Full Text PDFFront Robot AI
January 2025
CREATE Lab, Institute of Mechanical Engineering, School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
Laboratory automation requires reliable and precise handling of microplates, but existing robotic systems often struggle to achieve this, particularly when navigating around the dynamic and variable nature of laboratory environments. This work introduces a novel method integrating simultaneous localization and mapping (SLAM), computer vision, and tactile feedback for the precise and autonomous placement of microplates. Implemented on a bi-manual mobile robot, the method achieves fine-positioning accuracies of 1.
View Article and Find Full Text PDFInfancy
January 2025
Donders Institute for Brain, Cognition and Behavior, Radboud University, Nijmegen, The Netherlands.
The ability to recognize and act on others' emotions is crucial for navigating social interactions successfully and learning about the world. One way in which others' emotions are observable is through their movement kinematics. Movement information is available even at a distance or when an individual's face is not visible.
View Article and Find Full Text PDFJ Psychiatr Pract
January 2025
University of Texas Southwestern, Dallas, TX.
Korean Americans have one of the highest rates of depression of the Asian subgroups in the United States, and they have culture-related factors that affect their mental health. It is important for health care providers to understand the cultural considerations of Korean Americans to better address their mental health. This review article delves into the pertinent cultural practices of Korean Americans for navigating discussions of mental health.
View Article and Find Full Text PDFWorld J Urol
January 2025
Department of Urology, Beijing Jishuitan Hospital, Capital Medical University, Beijing, 102208, China.
Purpose: The objective of this study was to explore the feasibility of using the TianJi Robot system for navigated needle positioning in the PCNL procedure in vitro.
Methods: A pig kidney with a segment of ureter was selected as the in vitro organ model. Iodine contrast agent was infused into the renal pelvis to dilate the renal pelvis and calyx to establish the in vitro hydronephrosis model.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!