Laser Doppler field sensor for high resolution flow velocity imaging without camera.

Appl Opt

Department of Electrical Engineering and Information Technology, Dresden University of Technology, Helmholtzstrasse 18, 01069 Dresden, Germany.

Published: September 2008

In this paper we present a laser sensor for highly spatially resolved flow imaging without using a camera. The sensor is an extension of the principle of laser Doppler anemometry (LDA). Instead of a parallel fringe system, diverging and converging fringes are employed. This method facilitates the determination of the tracer particle position within the measurement volume and leads to an increased spatial and velocity resolution compared to conventional LDA. Using a total number of four fringe systems the flow is resolved in two spatial dimensions and the orthogonal velocity component. Since no camera is used, the resolution of the sensor is not influenced by pixel size effects. A spatial resolution of 4 microm in the x direction and 16 microm in the y direction and a relative velocity resolution of 1x10(-3) have been demonstrated up to now. As a first application we present the velocity measurement of an injection nozzle flow. The sensor is also highly suitable for applications in nano- and microfluidics, e.g., for the measurement of flow rates.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.47.005028DOI Listing

Publication Analysis

Top Keywords

laser doppler
8
imaging camera
8
sensor highly
8
velocity resolution
8
microm direction
8
sensor
5
resolution
5
flow
5
velocity
5
doppler field
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!