Context: Few studies of inter- or intraobserver reliability have focused on evaluations of cranial strain patterns.

Objective: To determine whether substantial intraobserver reliability can be achieved by osteopathic physicians (DOs) using common palpatory tests to diagnose cranial dysfunction.

Methods: Forty-eight subjects were divided into three diagnostic groups, categorized as those with asthma, headaches, or neither asthma nor headaches (ie, healthy control group). Two blinded DO examiners separately evaluated approximately 8 subjects from each group (4 subjects per session), conducting diagnostic tests for cranial rhythmic impulse (CRI) rate, cranial strain patterns, and quadrants of restriction.

Results: Overall, among the three diagnostic procedures, cranial strain patterns showed the highest intraobserver reliability (kappa=0.67). The highest intraobserver reliability was achieved in cranial strain patterns for the control group (kappa=0.82), followed by the headache (kappa=0.67) and asthma (kappa=0.52) groups. Diagnoses of the left anterior quadrant of restriction also showed substantial intraobserver reliability for the headache and control groups (kappa=0.60 and 0.61, respectively). Diagnoses of three quadrants of restriction showed moderate overall intraobserver reliability (kappa=0.44-0.52), while the left posterior quadrant had only fair overall intraobserver reliability (kappa=0.33).

Conclusion: Osteopathic physicians can obtain substantial intraobserver reliability when diagnosing cranial strain patterns in healthy subjects as well as those with asthma or headache. However, results are less promising for diagnoses of CRI and quadrants of restriction.

Download full-text PDF

Source

Publication Analysis

Top Keywords

intraobserver reliability
36
cranial strain
24
strain patterns
20
osteopathic physicians
12
substantial intraobserver
12
intraobserver
9
cranial
8
reliability
8
reliability achieved
8
three diagnostic
8

Similar Publications

Purpose: No studies have explored the reliability of the Rigo classification system using surface topography (ST), which would allow optimization without radiation exposure. This study aims to measure and compare the intra- and inter-observer reliability (Kappa values) and accuracy of the Rigo system between ST and X-ray for overall types and subtypes.

Methods: X-ray and ST images of 31 adolescent idiopathic scoliosis patients were selected.

View Article and Find Full Text PDF

Objectives: Multiple techniques have been proposed for functional fetal cardiology, including pulsed-wave (PW) and tissue Doppler imaging (TDI), Myocardial Performance Index (MPI), annular plane systolic excursion (TAPSE/MAPSE) and spatiotemporal image correlation (STIC). We aimed to compare these techniques' achievability and reproducibility to determine their clinical utility for each cardiac side.

Methods: Uncomplicated pregnancies from 22 to 39 weeks were recruited and images and volumes stored for offline analysis.

View Article and Find Full Text PDF

Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application.

View Article and Find Full Text PDF

The diagnostic workup of primary lymphedema includes lymphoscintigraphy, a diagnostic test that provides objective data derived from the characteristics of the lymphatic flow and the lymphatic nodes. Several empirical scoring systems have been proposed with the aim of harmonizing the procedure. Here we comment the latest one, reflecting on the relevance of these tools to make possible multicenter research, based on intraobserver and interobserver reliability with the aim to, in the long run, improve patient outcomes.

View Article and Find Full Text PDF

A new classification for dislocated and displaced proximal humeral fractures.

J Orthop Surg Res

January 2025

Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, 2-1-1 Minatojima-minamimachi, Chuo-ku, Kobe, 650-0047, Japan.

Background: Although the Neer and AO/OTA classifications have been widely accepted, observer reliability studies of these two classifications have questioned their reliability and reproducibility to date. We developed an entirely new classification, the Mitsuzawa classification, for dislocated and displaced proximal humeral fractures and tested all three classifications for their intra- and interobserver reliability.

Methods: Two experienced shoulder surgeons and two orthopedic residents independently evaluated the Xray (xR) values of 100 proximal humeral fractures (PHFs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!