A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Notched stress-strain behavior of a conventional and a sequentially annealed highly crosslinked UHMWPE. | LitMetric

Notched stress-strain behavior of a conventional and a sequentially annealed highly crosslinked UHMWPE.

Biomaterials

Musculoskeletal Mechanics and Materials Laboratories, Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA.

Published: December 2008

Contemporary total joint replacement designs contain stress-risers such as fillets, grooves, and undercuts; therefore, it is of interest to analyze the behavior of UHMWPEs in the presence of such design-related stress-risers. This study examined the engineering and true axial stress-strain behavior of smooth cylindrical and notched cylindrical test specimens, under applied axial tensile loading (2 displacement rates, 37 degrees C) for a conventional and a highly crosslinked second generation UHMWPE. Both materials were prepared from ram extruded GUR 1050. The conventional material (30 kGy) was gamma sterilized at 30 kGy in an inert N(2) environment. The sequentially annealed material (SA) was gamma irradiated at 30 kGy and annealed for 8h at 130 degrees C. The irradiation-annealing process was repeated two more times for an overall irradiation dose of 90 kGy. Differential scanning calorimetry (DSC) was utilized to investigate changes in crystallinity and lamellar thickness distributions upon loading. Fractographic analysis of scanning electron microscope (SEM) images of fracture surfaces was performed to investigate changes in fracture micromechanism with notching. Both the 30 kGy and SA materials, in the smooth condition, demonstrated substantial ductility and orientation hardening. With the introduction of a notch, both materials demonstrated an elevation in the yield stress (notch strengthening) and a reduction in the ultimate stress and ultimate strain at both displacement rates. Additionally, it was found that the uniaxial stress-state (smooth condition) allowed for greater changes in crystallinity and the lamellar thickness distributions, when compared to the untested materials, than the triaxial stress-state induced by the notched geometry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3573887PMC
http://dx.doi.org/10.1016/j.biomaterials.2008.08.010DOI Listing

Publication Analysis

Top Keywords

stress-strain behavior
8
sequentially annealed
8
highly crosslinked
8
displacement rates
8
investigate changes
8
changes crystallinity
8
crystallinity lamellar
8
lamellar thickness
8
thickness distributions
8
smooth condition
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!