A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Identification and quantification of two antihepatotoxic coumarinolignoids cleomiscosin A and cleomiscosin B in the seeds of Cleome viscosa using liquid chromatography-tandem mass spectrometry. | LitMetric

A sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed for the identification and quantification of two antihepatotoxic coumarinolignoids cleomiscosin A and cleomiscosin B in different extracts of the seeds of Cleome viscosa. The separation of cleomiscosin A and cleomiscosin B was achieved on an RP(18) column using a solvent system consisting of a mixture of acetonitrile-methanol (1:2, v/v) and acetonitrile-water-formic acid (5:95:0.3, v/v) as a mobile phase in a gradient elution mode. A multiple-reaction monitoring (MRM) method was developed for quantification of cleomiscosin A and cleomiscosin B in the seed extracts of Cleome viscosa. On the basis of signal-to-noise ratio of 3, the limit of detection in MRM mode for cleomiscosin A and cleomiscosin B were 1.0 and 4.0 ng/mL respectively. The method was validated in terms of linearity, accuracy and precision for 6 days. The method developed was found to be useful for identification and quantification of cleomiscosin A and cleomiscosin B in the different extracts of the seeds of Cleome viscosa.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.1121DOI Listing

Publication Analysis

Top Keywords

cleomiscosin cleomiscosin
24
cleome viscosa
16
identification quantification
12
cleomiscosin
12
seeds cleome
12
method developed
12
quantification antihepatotoxic
8
antihepatotoxic coumarinolignoids
8
coumarinolignoids cleomiscosin
8
developed identification
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!