In daily clinical practice, implanted fiducial markers are used to correct for prostate motion, but not for prostate deformation. The aim of this study is to investigate the variation in target and rectum dose due to the deformation of the prostate gland (without seminal vesicles). Therefore, we performed five to six MRI scans of eight healthy volunteers that exhibited large variation in rectal volume and thus prostate deformation. Prostate motion was corrected by a mask-based rigid registration which uses the delineation as well as the internal structures of the prostate gland. Per MRI scan, one IMRT plan with a PTV margin of 4 mm was created, resulting in 41 IMRT plans. The dose distribution of the IMRT plan based on the MRI scan with the minimum rectal volume was applied to the other rigidly registered MRI scans to evaluate the impact of prostate deformation. In conclusion, pre-treatment planning on the minimum rectal volume can cause a fraction dose increase (up to 15%) to the rectum due to prostate deformation. The impact on the total dose increase to the rectum depends on the intrapatient rectum variation during treatment, but is negligible with the currently used PTV margins in a fractionated treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/53/20/004 | DOI Listing |
Medicina (Kaunas)
December 2024
Medical College, Medical University of Plovdiv, 4002 Plovdiv, Bulgaria.
Situs anomalies, including situs inversus and situs ambiguous (SAMB), are rare congenital conditions typically noted in pediatric populations, with SAMB being particularly uncommon in adults. This case study addresses the incidental discovery of situs ambiguous with polysplenia in a 65-year-old man evaluated for suspected adrenal adenoma. The patient's medical history included benign prostatic hyperplasia and tuberculous pleurisy.
View Article and Find Full Text PDFInt Cancer Conf J
January 2025
Department of Urology, The Second Affiliated Hospital of Xi'an Jiaotong University, No. 157 Xiwu Road, Xi'an, 710004 China.
Mismatch repair deficiency (MMRd) or microsatellite instability high (MSI-H) is rare in prostate cancer and more frequently observed in cases with ductal histology. MLH1 copy number loss is extremely rare in MMRd tumors. Herein, we describe a case of prostate ductal adenocarcinoma with MLH1 copy number loss, microsatellite instability high and BRCA2 mutation could derive benefit from immunotherapy plus ADT.
View Article and Find Full Text PDFPediatr Surg Int
December 2024
Department of Pediatric Surgery, Hokkaido Medical Center for Child Health and Rehabilitation, 1-1-240-6, Kanayama, Teine-ku, Sapporo, Hokkaido, 006-0041, Japan.
Purpose: This study aimed to identify surgical site infection (SSI) risk factors after anal reconstruction surgery in patients with anorectal malformations (ARMs).
Methods: This retrospective analysis from January 2013 to December 2022, including all pediatric surgical facilities in Hokkaido, Japan, examined consecutive patients with ARMs, excluding cloacal cases, regarding perioperative and SSI factors during their initial anal reconstruction surgeries.
Results: This study involved 157 cases of major clinical groups and 7 cases of rare/regional variants, among whom 4% developed SSIs.
J Appl Clin Med Phys
December 2024
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: This study assesses a novel, automated dose accumulation process during MR-guided online adaptive radiotherapy (MRgART) for prostate cancer, focusing on inter-fractional anatomical changes and discrepancies between delivered and planned doses.
Methods: A retrospective analysis was conducted on seven prostate cancer patients treated with a five-fraction stereotactic body radiation therapy (SBRT), using a 0.35T MRIdian MR-LINAC system.
J Cancer Biol Res
February 2024
Department of Mechanical and Aerospace Engineering, University of Central Florida, USA.
The examination of the prostate biopsy procedure is essential in the optimization of the diagnostic pathway of such a prevalent affliction as prostate cancer among men worldwide. With the core needle biopsy being the standard of care for the diagnosis of prostate cancer, the ability to obtain quality core samples is directly related to patient treatment and diagnostic reliability. Needle deflection and dynamic tissue deformation are two chief sources of unrepresentative samples outside of human error.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!