Introduction: Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning.

Methods: Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention.

Results: The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation.

Conclusions: Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2592749PMC
http://dx.doi.org/10.1186/cc7015DOI Listing

Publication Analysis

Top Keywords

critically ill
16
ill patients
16
sedative analgesic
16
analgesic drugs
16
electroencephalographical parameters
16
entropy bispectral
12
processed electroencephalography
12
processed electroencephalographical
12
drug administration
12
sedation
8

Similar Publications

Structural and Functional Glycosylation of the Abdala COVID-19 Vaccine.

Glycobiology

January 2025

Department of Biochemistry, Dorothy Crowfoot Hodgkin Building, University of Oxford, South Parks Road, OX1 3QU, United Kingdom.

Abdala is a COVID-19 vaccine produced in Pichia pastoris and is based on the receptor-binding domain (RBD) of the SARS-CoV-2 spike. Abdala is currently approved for use in multiple countries with clinical trials confirming its safety and efficacy in preventing severe illness and death. Although P.

View Article and Find Full Text PDF

Multi-disciplinary treatment of broncho-esophageal fistula in a high-risk single-lung patient.

J Cardiothorac Surg

January 2025

Section of Cardiothoracic Surgery, Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, 5021, Bergen, Norway.

Background: A broncho-esophageal fistula (BEF) is a medical and surgical disaster. Treatment of BEF is often limited to palliative stent treatment that may migrate or cause erosions and tissue necrosis. Surgical repair of BEF is the only established definite treatment.

View Article and Find Full Text PDF

Early urea-to-creatinine ratio to predict rapid muscle loss in critically ill patients with sepsis: a single-center retrospective observational study.

BMC Anesthesiol

January 2025

Jiangsu Provincial Key Laboratory of Critical Care Medicine, Department of Critical Care Medicine, School of Medicine, Zhongda Hospital, Southeast University, Nanjing, 210009, China.

Background: Patients with sepsis in the intensive care unit (ICU) often experience rapid muscle loss. The urea-to-creatinine ratio (UCR) is thought to reflect muscle breakdown (creatinine) and catabolism (urea) and is commonly used to assess nutritional and metabolic status. This study aimed to investigate whether changes in UCR (ΔUCR) can predict the development of rapid muscle loss in patients with sepsis.

View Article and Find Full Text PDF

The benefits of using continuous glucose monitoring (CGM) in hospitalized patients with diabetes remain uncertain. Point-of-care (POC) glucose testing is the standard of care in this setting. We compared the effect of adding CGM to POC testing versus POC testing alone on glycemic outcomes in this population.

View Article and Find Full Text PDF

Background: Gut microbiota disturbance may worsen critical illnesses and is responsible for the progression of multiple organ dysfunction syndrome. In our previous study, there was a trend towards a higher α-diversity of the gut microbiota in sequential feeding (SF) than in continuous feeding (CF) for critically ill patients. We designed this non-blinded, randomized controlled study to confirm these results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!